Home Automation (WMP) – Samsung NASA
TM
Intesis
396
DC voltage sensor error of Fan2
399
Heat sink temperature sensor error of Fan2
400
Error due to overheat caused by contact failure on IPM of Inverter PBA2
407
Compressor operation stop due to high pressure protection control
410
Compressor operation stop due to low pressure protection control or refrigerant leakage
416
Compressor operation stop due to discharge temperature protection control
Phase reversal or phase failure (3Ø outdoor unit wiring, R-S-T-N ), connection error on 3 phase
425
input
428
Compressor operation stop due abnormal compression ratio
EVI (ESC) EEV leakage or internal leakage of intercooler or incorrect connector insertion of EVI
438
(ESC) EEV
439
Error due to refrigerant leakage
440
Heating mode restriction due to high air temperature
441
Cooling mode restriction due to low air temperature
442
Refrigerant charing restriction in heating mode when air temperature is over 15 °C
443
Operation prohibited due to the pressure drop
445
CCH is deatched
446
Error due to operation failure of Fan1
447
Motor wire of Fan1 is not connected
448
Lock error on Fan1
452
Error due to ZPC detection circuit problem or power failure
453
Error due to overheated motor of outdoor unit's Fan1
455
Error due to overheated IPM of Fan1
461
Error due to operation failure of inverter compressor 1
462
Compressor stop due to full current control or error due to low current on CT2
464
Error due to over-current of inverter compressor 1
465
V-limit error of inverter compressor 1
466
Error due to over voltage /low voltage of inveter PBA1
467
Error due to unconnected wire of compressor 1
468
Output current sensor error of inverter PBA1
469
DC voltage sensor error of inver PBA1
474
Heat sink temperature sensor error of inverter PBA1
478
Error due to overcurrent of Fan1
485
Error due to input current of inverter 1
486
Error due to over voltage/low voltage of Fan
487
Hall IC error of Fan1
489
V-limit error on Fan1 of compressor
493
Output current sensor error of Fan1
496
DC voltage sensor error of Fan1
499
Heat sink temperature sensor error of Fan1
500
Error due to overheat caused by contact failure on IPM of Inverter PBA1
503
Error due to alert the user to check if the service valve is closed
504
Error due to self diagnosis of compressor operation
505
Error due to self diagnosis of high pressure sensor
506
Error due to self diagnosis of low pressure sensor
560
Outdoor unit's option switch setting error (when iinappropriate option switch is on)
Error due to module installation of indoor unit with old version (Micom version needs to be
563
checked)
573
Error due to using single type outdoor unit in a module installation
601
Communication error between remote controller and the DVM Hydro unit / Hydro unit HT
602
Communication error between master and slave remote controller