HMS Networks Intesis WMP User Manual page 23

Table of Contents

Advertisement

Home Automation (WMP) – Samsung NASA
TM
Intesis
When total number of indoor units assigned to MCU is same as actual number of installed
213
indoor units but there is indoor unit that is not installed even though it is assigned on MCU
When number of MCU is not set correctly on the outdoor unit or when two or more MCU was
214
installed some of them have the same address
When two different MCU's have same address value on the rotary switch
215
216
When indoor unit is not installed to a MCU port but the switch on the port is set to On.
hen indoor unit is connected to a MCU port but indoor unit is assigned to a MCU and the switch
217
on the port is set to Off
When there's at least one or more actual number of indoor unit connection compared to
218
number of indoor units assigned to MCU
219
Error on temperature sensor located on MCU intercooler inlet (Short or Open)
220
Error on temperature sensor located on MCU intercooler outlet (Short or Open)
221
Error on outdoor temperature sensor of outdoor unit (Short or open)
231
Error on COND OUT temperature sensor of main outdoor unit (Short or Open)
241
COND OUT sensor is detached
251
Error on discharge temperature sensor of compressor 1 (Short or Open)
257
Error on discharge temperature sensor of compressor 2 (Short or Open)
262
Discharge temperature sensor of compressor 1 is detached from the sensor holder on the pipe
263
Discharge temperature sensor of compressor 2 is detached from the sensor holder on the pipe
266
Top sensor of compressor 1 is detached
267
Top sensor of compressor 2 is detached
269
Suction temperature sensor is detached from the sensor holder on the pipe
276
Error on top sensor of compressor 1 (Short or Open)
277
Error on top sensor of compressor 2 (Short or Open)
291
Refrigerant leakage or error on high pressure sensor (Short or Open)
296
Refrigerant leakage or error on low pressure sensor (Short or Open)
308
Error on suction temperature sensor (Short or Open)
Error on temperature sensor of double layer pipe/liquid pipe(sub heat exchanger) (Short or
311
Open)
321
Error on EVI (ESC) IN temperature sensor (Short or Open)
322
Error on EVI (ESC) OUT temperature sensor (Short or Open)
323
Error on suction sensor 2 (Short or Open)
346
Error due to operation failure of Fan2
347
Motor wire of Fan2 is not connected
348
Lock error on Fan2 of outdoor unit
353
Error due to overheated motor of outdoor unit's Fan2
355
Error due to overheated IPM of Fan2
361
Error due to operation failure of inverter compressor 2
364
Error due to over-current of inverter compressor 2
365
V-limit error of inverter compressor 2
366
Error due to over voltage /low voltage of inverter PBA2
367
Error due to unconnected wire of compressor 2
368
Output current sensor error of inverter PBA2
369
DC voltage sensor error of inverter PBA2
374
Heat sink temperature sensor error of inverter PBA2
378
Error due to overcurrent of Fan2
385
Error due to input current of inverter 2
386
Over-voltage/low-voltage error of Fan2
387
Hall IC connection error of Fan2
389
V-limit error on Fan2 of compressor
393
Output current sensor error of Fan2
© HMS Industrial Networks S.L.U. - All rights reserved
This information is subject to change without notice
User Manual r1.0 EN
URL
https://www.intesis.com
23 / 25