Articulating arm

Advertisement

StrongArmPark DC: Lighting Connection for Articulated Arm
1. Make sure both AC and DC power switches are turned OFF.
2. Insert leads of wire harness through the hole in chassis between the two bracket mounts. Feed the
cable through the interior of the chassis. Pull enough cable to reach the Smart DC Controller terminals.
NOTE: Connect wire lead to 24VDC. Lights are dim when connected to 12VDC.
3. Attach the end of the wire harness (on the outside of the chassis) to the LED light connector on the
arm. The wire harness connector is keyed. Be sure to seat the connectors before threading close.
CAUTION
To allow full arm travel, the cable loop on the outside of the chassis must be a minimum 8-inches (20 cm) in length.
4. Secure the harness to the chassis with the strain relief bushing.
Remove smaller
plugs to mount
articulating arm
strut.
Remove center plug
to feed wire harness
cable through
chassis.
Remove Plugs in Chassis
Cable loop length:
8-inches (20 cm)
www.hysecurity.com
© 2017
Secure cable
with strain relief
bushing.
Feed Cable through Chassis
Connect Articulating Arm Cable
Page 3
DC Power
Switch
AC Power
Switch
LED Arm Light
connector
Wire harness
connector