If you meets the high standards set by Beverage-Air! You have have any questions, Please call our Technical Service made a quality investment that with proper maintenance Department at (800) 684-1195.
R290 equipment. • Clean a dirty condenser with a sharp object. • Use ONLY Beverage-Air factory service parts. Use of • Store gasoline, kerosene or any other flammable non OEM parts can be dangerous because of the design material near the cabinet.
User Manual for GF Glass Freezers Beverage-Air IMPORTANT INFORMATION This unit is intended to be used in a commercial application. That includes bars and restaurants. If installed in a residence some commercial service companies may not be able to service it on site.
Solid Load w x d x h (Inches) Plug (NEMA) Charge g /Charge oz Door Amps GF24HC 24 1/8 x 26 1/8 x 33 5/8 Solid GF34HC 34 x 26 1/8 x 33 5/8 Solid 5-15P R-290 / 60 / 2.12...
User Manual for GF Glass Freezers Beverage-Air CLEARANCE AND PLACEMENT Placement Consider the following when selecting a location for your Refrigerator: Clearance: • Must not be covered - Top • 0" - Left • 0" - Right • 2" - Rear •...
User Manual for GF Glass Freezers Beverage-Air UNPACKING AND SET UP Carefully inspect the shipping carton for damage. This is the only time that shipping damage may be claimed. If damage is suspected, open the carton immediately and, if there is damage, retain the carton and contact the shipper to make a claim.
User Manual for GF Glass Freezers Beverage-Air ELECTRICAL This is a cord-connected unit, and must be connected to its own dedicated power supply. Check the dataplate on the machine to confirm the voltage and per the dataplate use the correct fuses or HACR circuit breakers.
User Manual for GF Glass Freezers Beverage-Air USING THE UNIT Operation is simple, just keep it connected to the correct The compressor and condenser fan motor will only be on power supply and the refrigerator will maintain the when the controller senses an increase in internal cabinet internal temperature it has been set to.
User Manual for GF Glass Freezers Beverage-Air SEQUENCE OF OPERATIONS FREEZER The refrigerator operates based on the air temperature measured by the probe located at the return air. COMPONENT OPERATION CONTROLLER ACTION OPERATION CONTROLLER ACTION Compressor turns The Compressor The Compressor...
Page 11
User Manual for GF Glass Freezers Beverage-Air User Manual for PFI Freezers Beverage-Air User Manual for UCF Freezers Beverage-Air Keyboard Functions DEFROST (ESC) DOWN SET (ENTER) Quick press and release Quick press and release Quick press and release Quick press and release •...
User Manual for GF Glass Freezers Beverage-Air CLEANING AND MAINTENANCE Cleaning Schedule: Cabinet Condenser coil Gaskets Routine maintenance Daily wipe down Quarterly cleaning Daily inspection Annually Weekly interior Daily Exterior Cleaning It is much easier to clean on a regular basis than to have to remove stains once they have built up.
User Manual for GF Glass Freezers Beverage-Air CONDENSER CLEANING Keeping the condenser coil clean is critical to efficient operation. 1. Unplug unit from power supply. Rotating fan blade can cause CAUTION personal injury. Unplug unit from power supply before beginning to clean condenser 2.
User Manual for GF Glass Freezers Beverage-Air METHODS FOR CLEANING STAINLESS STEEL Cleaning Needed Cleaning Agent Method of Application Affect on Finish Satisfactory for use on all Areal 20, Lac-O-Nu, Lumin Wash Rub with cloth as directed finishes. Smears and fingerprints O’Cedar Cream Polish, Stainless...
User Manual for GF Glass Freezers Beverage-Air HELP Trouble Diagnosis for the User Malfunction Possible Cause Likely Solution Connect to proper voltage circuit Replace Unit not plugged in. fuse or reset breaker. No cooling - unit is silent Fuse or circuit breaker tripped.
User Manual for GF Glass Freezers Beverage-Air FOR THE SERVICE TECH - R290 Refrigeration service should only be attempted by a trained trade professional certified to work on R290 systems. Here are some critical service items. Other Information: This list does not qualify anyone to service the unit. It is a Evacuation: It is critical that a refrigeration system be reminder and checklist for the service tech.
(87) months from the date of defective. shipment from Beverage-Air, provided upon receipt of the The labor warranty shall be for self-contained units compressor, manufacturer examination shows the sealed only and for standard straight time, which is defined as compressor to be defective.
With the exception of Blast Chillers product is designed for LIMITATION OF LIABILITY: maintaining temperature and not bringing food to a desired Beverage-Air Corporation or their affiliates shall not be temperature therefore cannot be held responsible for this liable for any indirect, incidental, special or consequential function under warranty.
Page 22
User Manual for GF Glass Freezers Beverage-Air Warranty Registration Register your product online at beverage-air.com/parts-service or fill out and mail the form below. Cabinet Model Number: _____________________________________________ Date Of Installation: _________________ Cabinet Serial Number: _____________________________________________ Location Of Product Business Name: ____________________________________________________...