Do you have a question about the Slate Series and is the answer not in the manual?
Questions and answers
Doulas Cale
July 9, 2025
Getting beeping and error code AH. Unit still should be at factory settings but lowest temp it gets to is 8F. Model SF2HC-1S, SN 0025895-30766-A installed 8-31-23.
User Manual for Slate Beverage-Air WELCOME Thank you for purchasing a Beverage-Air cabinet. This Please read the following installation and maintenance series has passed our strict quality control inspection instructions before installing or using your unit. If you and meets the high standards set by Beverage-Air...
R290 equipment. • Clean a dirty condenser with a sharp object. • Use ONLY Beverage-Air factory service parts. Use of • Store gasoline, kerosene or any other flammable non OEM parts can be dangerous because of the design material near the cabinet.
User Manual for Slate Beverage-Air IMPORTANT INFORMATION This unit is intended to be used in a commercial application. That includes bars and restaurants. If installed in a residence some commercial service companies may not be able to service it on site.
User Manual for Slate Beverage-Air PRODUCT INFORMATION Cabinet Dimensions Full Load Refrigerant Charge Model Door Count Shelves Compressor HP w x d x h (Inches) Amps (g) (R-290) 2.82 oz = 80 grams SF1HC-1S 30.1 x 33.5 x 77.8 4.93 oz = 140 grams SF2HC-1S 52 x 34.9 x 77.8...
User Manual for Slate Beverage-Air CLEARANCE AND PLACEMENT Placement Consider the following when selecting a location for your cooler: • Clearance: 4 inches at back. None at sides. • Floor Load: the floor on which the cooler is located must be even and level, free from vibrations, and strong enough to support the combined weights of the unit and maximum product load.
User Manual for Slate Beverage-Air UNPACKING AND SET UP Carefully inspect the shipping carton for damage. This is the only time that shipping damage may be claimed. If damage is suspected, open the carton immediately and, if there is damage, retain the carton and contact the shipper to make a claim.
4. Install all remaining clips. manner. Contact Beverage-Air customer service if fewer shelves or a different configuration to ensure 5. Install shelves onto clips with the product retention shelf overloading will not occur.
User Manual for Slate Beverage-Air ELECTRICAL This is a cord-connected unit, and must be connected to its own dedicated power supply. Check the dataplate on the machine to confirm the voltage and per the dataplate use the correct fuses or HACR circuit breakers.
User Manual for Slate Beverage-Air USING THE UNIT Operation is simple, just keep it connected to the correct power supply and the refrigerator will maintain the The refrigerator will automatically defrost as needed, internal temperature it has been set to. Keep the doors there is no set time for defrost.
User Manual for Slate Beverage-Air CLEANING AND MAINTENANCE Cleaning Schedule: Cabinet Condenser coil Gaskets Routine maintenance Daily wipe down Quarterly cleaning Daily inspection, check Annually that hinges are tight to Weekly interior the cabinet. Every two years. Daily Exterior Cleaning It is much easier to clean on a regular basis than to have to remove stains once they have built up.
User Manual for Slate Beverage-Air CONDENSER CLEANING Keeping the condenser coil clean is critical to efficient 3. Pull grill carefully out and off the cabinet. operation. 1. Unplug unit from power supply. Rotating fan blade can cause CAUTION personal injury.
User Manual for Slate Beverage-Air METHODS FOR CLEANING STAINLESS STEEL Cleaning Needed Cleaning Agent Method of Application Affect on Finish Satisfactory for use on all Areal 20, Lac-O-Nu, Lumin Wash Rub with cloth as directed finishes. Smears and fingerprints O’Cedar Cream Polish, Stainless on the package.
User Manual for Slate Beverage-Air HELP Trouble Diagnosis for the User Malfunction Possible Cause Likely Solution Connect to proper voltage circuit Replace Unit not plugged in. fuse or reset breaker. No cooling - unit is silent Fuse or circuit breaker tripped.
The illustration below is an example of what is available. Beverage-Air assumes no liability or responsibility of any kind for products manufactured by Beverage-Air that have been altered in any way, including the use of any part and/or other components not specifically approved by Beverage-Air.
User Manual for Slate Beverage-Air FOR THE SERVICE TECH Refrigeration service should only be attempted by a trained trade professional certified to work on R290 systems. Here are some critical service items. Other Information: This list does not qualify anyone to service the unit. It is a Evacuation: It is critical that a refrigeration system be reminder and checklist for the service tech.
(63) months from the date of additional overtime rate will be at the responsibility of the shipment from Beverage-Air, provided upon receipt of the equipment purchaser. compressor, manufacturer examination shows the sealed compressor to be defective.
Page 18
God. Warranty Registration Register your product online at beverage-air.com/parts-service or fill out and mail the form below. Cabinet Model Number: _____________________________________________ Date Of Installation: _________________ Cabinet Serial Number: _____________________________________________...
Need help?
Do you have a question about the Slate Series and is the answer not in the manual?
Questions and answers
Getting beeping and error code AH. Unit still should be at factory settings but lowest temp it gets to is 8F. Model SF2HC-1S, SN 0025895-30766-A installed 8-31-23.