If you meets the high standards set by Beverage-Air! You have have any questions, Please call our Technical Service made a quality investment that with proper maintenance Department at (800) 684-1195.
R290 equipment. • Clean a dirty condenser with a sharp object. • Use ONLY Beverage-Air factory service parts. Use of • Store gasoline, kerosene or any other flammable non OEM parts can be dangerous because of the design material near the cabinet.
User Manual for UCF Freezers Beverage-Air IMPORTANT INFORMATION This unit is intended to be used in a commercial application. That includes schools and cafeterias. If installed in a residence some commercial service companies may not be able to service it on site.
User Manual for UCF Freezers Beverage-Air PRODUCT INFORMATION Door or Cabinet Dimensions Full Load Power Cord Refrigerant Type / Model Door Type Drawer w x d x h (Inches) Amps Plug (NEMA) Charge (g) / (oz) Count UCF20HC 20 x 24 1/2 x 31 1/8...
User Manual for UCF Freezers Beverage-Air CLEARANCE AND PLACEMENT 0" MINIMUM CLEARANCE 0" 3" 2" LEFT/RIGHT SIDE BOTTOM REAR MINIMUM MINIMUM MINIMUM CLEARANCE CLAERANCE CLEARANCE Placement Consider the following when selecting a location for your freezer: Clearance: • 0 in. at the top •...
User Manual for UCF Freezers Beverage-Air UNPACKING AND SET UP Carefully inspect the shipping carton for damage. This is the only time that shipping damage may be claimed. If damage is suspected, open the carton immediately and, if there is damage, retain the carton and contact the shipper to make a claim.
4. Install all remaining clips. manner. Contact Beverage-Air customer service if fewer shelves or a different configuration to ensure 5. Install shelves onto clips with the product retention shelf overloading will not occur.
User Manual for UCF Freezers Beverage-Air ELECTRICAL This is a cord-connected unit, and must be connected to its own dedicated power supply. Check the dataplate on the machine to confirm the voltage and per the dataplate use the correct fuses or HACR circuit breakers.
User Manual for UCF Freezers Beverage-Air USING THE UNIT Operation is simple, just keep it connected to the correct The freezer will automatically defrost as needed, there is power supply and the freezer will maintain the internal no set time for defrost. Push and immediately release the temperature it has been set to.
User Manual for UCF Freezers Beverage-Air SEQUENCE OF OPERATIONS FREEZER The freezer operates based on the air temperature measured by the probe located at the return air. CONTROLLER CONTROLLER COMPONENT OPERATION OPERATION ACTION ACTION Compressor turns Compressor turns The Compressor Contact...
Page 12
User Manual for UCF Freezers Beverage-Air Condition Cabinet Temp > Set point + 2.5 Cabinet Temperature <= Set point - 2.5 Defrost Electronic Controller DEFROST (ESC) SELECT (OK) DOWN Control Panel Display Defrost LED Alarm LED On fixed: Defrost active...
Page 13
User Manual for UCF Freezers Beverage-Air Keyboard Functions DEFROST (ESC) DOWN SET (ENTER) Quick press and release Quick press and release Quick press and release Quick press and release • Activates manual defrost • Increases Set Point • Decreases Set Point •...
Page 14
User Manual for UCF Freezers Beverage-Air Control Panel Connections Changing the Set point Beverage-Air Rev. 06/20...
Page 15
User Manual for UCF Freezers Beverage-Air Keyboard Functions Electronic Controller Alarms The alarm condition is always signaled by the alarm icon . To turn off the relative icon will continue flashing. NOTE: If alarm exclusion times are in progress (ALA folder of the parameter table), the alarm is not signaled.
User Manual for UCF Freezers Beverage-Air CLEANING AND MAINTENANCE Cleaning Schedule: Cabinet Condenser coil Gaskets Routine maintenance Daily wipe down Quarterly cleaning Daily inspection, check Annually that hinges are tight to Weekly interior the cabinet. Daily Exterior Cleaning It is much easier to clean on a regular basis than to have to remove stains once they have built up.
User Manual for UCF Freezers Beverage-Air DRAWER CLEANING AND MAINTENANCE Drawer models are shipped with the drawers already installed in the cabinets. Drawers are designed with slides which have locking mechanisms to prevent drawers from coming off cabinets during normal opening and closing operations.
User Manual for UCF Freezers Beverage-Air CONDENSER CLEANING Keeping the condenser coil clean is critical to efficient 6. To reinstall the rear panel line up the bottom of the operation. panel to the bottom of the unit keeping the screw holes lined up on the panel and on the unit.
User Manual for UCF Freezers Beverage-Air METHODS FOR CLEANING STAINLESS STEEL Cleaning Needed Cleaning Agent Method of Application Affect on Finish Satisfactory for use on all Areal 20, Lac-O-Nu, Lumin Wash Rub with cloth as directed finishes. Smears and fingerprints O’Cedar Cream Polish, Stainless...
User Manual for UCF Freezers Beverage-Air HELP Trouble Diagnosis for the User Malfunction Possible Cause Likely Solution Connect to proper voltage circuit Replace Unit not plugged in. fuse or reset breaker. No cooling - unit is silent Fuse or circuit breaker tripped.
User Manual for UCF Freezers Beverage-Air FOR THE SERVICE TECH - R290 Refrigeration service should only be attempted by a trained trade professional certified to work on R290 systems. Here are some critical service items. Other Information: This list does not qualify anyone to service the unit. It is a Evacuation: It is critical that a refrigeration system be reminder and checklist for the service tech.
User Manual for UCF Freezers Beverage-Air FOR THE SERVICE TECH - WIRING DIAGRAM CNTRL *SEE CONTROLLER DETAIL COMPRESSOR DETAIL CONDENSER FAN START RELAY S.C. COMP R.C. *SEE CONTROLLER DETAIL FACE HEATER DOOR HEATER GLASS DOOR MODELS ONLY *SEE CONTROLLER DETAIL...
(87) months from the date of defective. shipment from Beverage-Air, provided upon receipt of the The labor warranty shall be for self-contained units compressor, manufacturer examination shows the sealed only and for standard straight time, which is defined as compressor to be defective.
With the exception of Blast Chillers product is designed for LIMITATION OF LIABILITY: maintaining temperature and not bringing food to a desired Beverage-Air Corporation or their affiliates shall not be temperature therefore cannot be held responsible for this liable for any indirect, incidental, special or consequential function under warranty.
Page 25
User Manual for UCF Freezers Beverage-Air Warranty Registration Register your product online at beverage-air.com/parts-service or fill out and mail the form below. Cabinet Model Number: _____________________________________________ Date Of Installation: _________________ Cabinet Serial Number: _____________________________________________ Location Of Product Business Name: ____________________________________________________...
Need help?
Do you have a question about the UCF Series and is the answer not in the manual?