Download Print this page

Electrolux WHE7074SA Diagnostic Manual page 9

Double freezer westinghouse french door

Advertisement

MODEL: WHE7074SA Diagnostic Manual
Displayed
Step "76" is skipped
in this model
ARESI1004 Issue 1
Function test Actions Availible
code
62
Icemaker
Evaporator
Fan
63
Flip Mullion
Heater DC
66
Dispenser
Light
70
Fresh Food
Evaporator
Fan
VCZ Damper
76
Heater
80
DC Diverter
Valve for
Icemaker
81
DC Water
Pump
Copyright 2018 ELECTROLUX HOME PRODUCTS PTY LTD Technical Services
Press (CUBE) to
change the status of
the load
Press (CUBE) to
change the status of
the load
Press (CUBE) to
change the status of
the load
Press (CUBE) to
change the status of
the load
Press (CUBE) to
change the status of
the load
Press (CUBE) to
change the status of
the load
Press (CUBE) to
change the status of
the load.
10
Behaver Expected
a. "on" is showed in the refrigerator display
when icemaker evap fan is activated,
"oF" is showed when the fan is
deactivated.
b. Press (CUBE) button to change the
status.
a. DC Flip Mullion Heater is activated
when "on", deactivated when "oF"
b. Press (CUBE) button to change the
status.
a. Dispenser light on when "on", off when
"oF"
b. Press (CUBE) button to change the
status.
a. It is possible to run the Fresh Food
Evaporator Fan at 3 possible speeds.
b. Fan running maximum speed when "on";
n
medium speed when "
when "oF"
c. Press (CUBE) button to change the
status.
d. In case of Locked rotor condition the
refrigerator display shows "LC"
e. In case of absence of PWM signal that
provide duty cycle, the refrigerator
display shows "nS" when the fan is
"OF".
f.
In case of absence of 12V signal or
GND signal , the refrigerator display
shows "nP" when the fan is "on" or "Mi".
a. VCZ Damper Heater is activated when
"on", deactivated when "oF".
b. Press (CUBE) button to change the
status.
a. DC diverter Icemaker Valve moves to
icemaker position when "on" and come
back to normal position (water
dispenser) when "oF".
b. Press (CUBE) button to change the
status
a. DC Water Pump is piloted and it is
possible to have 3 states.
b. When pump is stopped "oF" is showed.
Then you have reverse piloting
displaying "rv".
L"; stopped

Advertisement

loading

This manual is also suitable for:

925060317-00