Behavior in Diagnostic Mode:
1. To enter diagnostic mode, press and hold + (freezer) and – (freezer) for 10 seconds.
2. On detection of 10-sec-holding of above buttons, all the Display LEDs on the External UI
Turn on & a beep tone will be heard
3. Press (Refrigerator) + button to progress through the different loads.
4. Press (Refrigerator) – button to come back to previous function.
5. Press (CUBE) button to change the status of the load.
6. Each load is associated with a number indicated in the Freezer Display and the Status is
shown in the Refrigerator Display. (See Service mode table below for details.)
Note: When there is the request to visualize some extra information more than the status of
the load (ex: freezer defrost heater and freezer defrost evaporator temperature), the
visualization on the displays is performed in this way:
Freezer Display: N° item
whilst testing the heater and sensor the value will be displayed in the fridge section
and alternate between value and status
Freezer Display
8. To EXIT from diagnostic mode, press and hold + (freezer) and – (freezer) buttons for 10
seconds. The appliance will restart in normal mode.
stages in order during the Diagnostic Mode
Function Test
Test
Initial diagnostic start up -
-
First Push "+"
-
ARESI1004 Issue 1
Copyright 2018 ELECTROLUX HOME PRODUCTS PTY LTD Technical Services
ns
Actio
Availible
-
6
:
Behavior Expected
a. Turns On all the LED's of the Display
a. Turns Off all the LED's of the Display
Refrigerator Display

Advertisement

loading

This manual is also suitable for:

925060317-00