WIRING DIAGRAMS
LEGEND for wiring diagram on following page
* FOR A HEAT PUMP THERMOSTAT USED
ON A STRAIGHT COOL UNIT.
** GL - LOW SPEED
GH - HIGH SPEED
CM
OUTDOOR FAN MOTOR
COMP
COMPRESSOR
DB
DAUGHTER BOARD
EM
EVAPORATOR MOTOR
FC
FAN CAPACITOR
F
FUSE
HPS
HIGH PRESSURE SWITCH
HTR
HEATER ELEMENT
MC
MAIN CONTROL
R
RELAY
RCCF
RUN CAPACITOR
FOR COMPRESSOR AND FAN
RVC
REVERSING VALVE
TR
TRANSFORMER
TB
TERMINAL BLOCK
VSM
VARIABLE SPEED MOTOR
VSTM
VARIABLE SPEED
TERMINAL BOARD
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.