RF600 system planning

4.3 Environmental conditions for transponders

4.3
Environmental conditions for transponders
4.3.1

Basic rules

The transponder must not be placed directly on metal surfaces or on containers of liquid. For
physical reasons, a minimum distance must be maintained between the tag antenna and
conductive material. A minimum distance of 5 cm is recommended. The tag function is
improved with greater distances (between 5 and 20 cm).
The best performance is achieved when the tag is mounted on a non-conductive material
such as plastic or wood.
Exception:
Tags that are designed for direct mounting on metal.
4-12
System Manual, 09/2005 Edition, J31069 D0171-U001-A0-7618,