3.2 Connection to Target System

There are two connection methods: connecting the connection tab of the option board to the target system directly
and connecting the connection tab of the option board to the target system via an extension probe.
(1) Connect the connectors to the target system. The connection methods vary depending on the target device, so
connect as shown in the figures below.
(a) When the target device is the V850E/MA1 (QFP package), V850E/IA1, V850E/IA2 (GC package)
Caution The direction of pin 1 is indicated on the NQPACKxxxSD. Refer to Figure 3-2.
CHAPTER 3
CONNECTION OF COMPONENTS
Figure 3-1. Connecting to Target System (1/5)
<3>
<1> Fix to the specified position by soldering.
<2> Insert.
<3> Fix using YQGUIDE.
User's Manual U14487EJ2V0UM
YQGUIDE
<3>
YQPACKxxxSD
<2>
NQPACKxxxSD
<1>
Target system