  • Page 1 RANGEHOOD & INSTALLATION GUIDE SCC1000-S SCC1000B-S SCC1000W-S www.schweigen.com.au Revision V6 26/09/2022...
  • Page 2 Index Welcome Important Safety Information Before Installation Product Use Electrical Cord Description Rangehood 4. Cleaning & Maintenance Cleaning the Interior Cleaning the Exterior Filters Installation Rangehood Size vs Cooktop Size Mounting Instructions Recommended Installation Height for Induction Cooktop Ceiling Cassette Installation Guide Optional Bulkhead Installation Guide Optional Side Port Installation (1600/3200 kit required) System Overview...
  • Page 3 The guide contains important information on the use and maintenance of the unit, as well as important safety notes. This will ensure your personal safety and the lasting value of your rangehood. We trust that you will enjoy your new Schweigen rangehood. Please always retain your proof of purchase to aid in any warranty queries.
  • Page 4 2. Important Safety Information WARNING Please read this section thoroughly before attempting to operate the appliance. Inspect your product upon receipt. Any damage or defects MUST be reported within 48 hours, or no claim will be recognised. DO NOT INSTALL THIS APPLIANCE IF YOU FIND IT DAMAGED. If this product is installed damaged, neither the supplier, nor the retailer, will be responsible for the costs associated with the repair, replacement, removal or re-installation of the appliances.
  • Page 5: Before Installation

    1. We recommend this appliance be installed or repaired by an experienced Home Appliances technician. 2. Please see our website www.schweigen.com.au for experienced installers. 3. It is dangerous to modify any part of this appliance. Modification of any kind, will immediately void the warranty.
  • Page 6: Range Hood

    3. Description _n_. _LH Section_ Rangehood 1. 200mm outlet 2. Twin Side Ports (1600/3200 kit required) 3. P.A. Filter Cover Panel 4. Filters 5. 2x Side adaptors 6. 2x Rectangle to round adators NOTE: Filter and light quantity may vary from model to model.
  • Page 7: Cleaning The Interior

    4. Cleaning & Maintenance Warning Always switch off and disconnect power before cleaning. Cleaning the Interior Clean the interior of the rangehood with a damp cloth and a neutral detergent. NOTE: Do not use denatured alcohol on the exterior of the rangehood. Do not clean the electric parts or the motor with liquids or solvents Cleaning the Exterior We recommended using a soft cloth, water and a liquid soap, rinsing it well and then drying it thoroughly.
  • Page 8 4. Cleaning & Maintenance Filters For this appliance to function effectively, regular maintenance is a must. • The function of the filter is to absorb the grease particles given off during cooking. • Clogged filters and heavy oil deposits restrict airflow and may cause the motor to overheat and become a fire hazard.
  • Page 9: Mounting Instructions

    Mounting Instructions The height and position of the rangehood in relation to the cooktop can greatly affect efficiency and extraction. After extensive testing, Schweigen recommends the following: Type of Cooktop Minimum Height Optimal Height Maximum Height...
  • Page 10 * Important: In addition to the information in this manual, please check all relevant state requirements for minimum– maximum heights, as well as regulations regarding the expelling of air. Schweigen is not liable if your rangehood is not installed in accordance with these legal requirements. Page 10...
  • Page 11 _n_. _RH Section_ 5. Installation Ceiling Cassette Installation Guide DANGER Always switch off and disconnect the power supply before installing the rangehood. Failure to do so may cause serious injury. WARNING Please remove filters before installation. Failure to do so may damage the clips. •...
  • Page 12 5. Installation _n_. _LH Section_ Optional Bulkhead Installation Guide DANGER Always switch off and disconnect the power supply before installing the rangehood. Failure to do so may cause serious injury. WARNING Please remove filters before installation. Failure to do so may damage the clips. •...
  • Page 13 _n_. _RH Section_ 5. Installation Optional Side port installation (1600/3200 kit required) DANGER Always switch off and disconnect the power supply before installing the rangehood. Failure to do so may cause serious injury. WARNING Please remove filters before installation. Failure to do so may damage the clips. This rangehood has an optional side Fig.
  • Page 14: System Overview

    5. Installation System Overview 1. Isodrive Motor ® 2. Roof Seal Kit (Dektite) (Not supplied)* 3. Support Straps (Not supplied)* 4. Attach Duct to Bell-Mouth Adaptor using ring clamp. Please DO NOT rip the ducting. 5. Isodrive Motor Power Lead (Plug). Connects ®...
  • Page 15: Faulty Installation

    Faulty Installation It is not the responsibility of Schweigen to rectify any incorrect installations. A service call out fee will be charged for any Schweigen technician that attends a call, whereby it is established that the fault is due to an incorrect installation or non-manufacturing fault. Should the appliance be installed in such a way that the service agent is unable to gain access to the appliance, the person/s who own the premises or the property where the appliance resides —...
  • Page 16: Cooking With Induction Cooktops

    6. Condensation Information Cooking with Induction Cooktops Cooking with an induction or similar cooktop, may produce condensation on the rangehood. Unlike basic electric or gas cooking, induction cooktops heat food and liquid instantly, which in turn, produces vapours rapidly. Because of this rapid process, the rangehood filters do not have enough time to warm, which increases the chance of condensation forming.
  • Page 17 In the event that the failure is not due to the faults mentioned in the Troubleshooting section, you can lodge an online Service Request. To lodge an online Service Request, visit our website www.schweigen. com.au/service-and-warranty and click on the link and complete the service request form.
  • Page 18: Technical Specifications

    8. Specifications _n_. _LH Section_ Dimensions Technical Specifications Model SCC1000-S / SCC1000B-S / SCC1000W-S Feeding Voltage 220-240V 50Hz Page 18...
  • Page 19 All information supplied is to be used for general reference purposes only and is on the understanding that Schweigen Home Appliances will not be liable for any loss, liability or damage of whatever kind arising as a result of any reliance upon such information.
  • Page 20 Australia Unit 4/1-5 Lake Drive, Dingley Village, Victoria 3172. Phone 1300 881 693 Email sales@schweigen.com.au Web www.schweigen.com.au New Zealand 5 Tolich Place, Henderson, Auckland 0610. Phone 0800 200 510 Email info.parex@emerson.com Web www.parex.co.nz...