Major Functions - Konica Minolta SpectraMagic NX Instruction Manual

Hide thumbs Also See for SpectraMagic NX:
Table of Contents

Advertisement

1.2 Major Functions

Items marked with
are supported only by SpectraMagic NX Professional Edition.
Color space
L*a*b*, L*C*h, Lab
Munsell C, Munsell D65 and their color differences (Excluding Munsell C and Mun-
sell D65)
Index
MI, WI (CIE1982 , ASTM E313-73 , ASTM E313-96 , HUNTER ,
BERGER , TAUBE , STENSBY , Ganz ), Tint (CIE1982 , ASTM E313-
96 , Ganz ), YI (ASTM D1925-70 , ASTM E313-73 , ASTM E313-96 ,
DIN6167 ), WB (ASTM E313-73) , Standard Depth (ISO 105.A06 ),
Brightness (TAPPI T452 , ISO2470 ), Opacity (ISO 2471 , TAPPI T425 89%
White Plate
Dominant Wavelength , Excitation Purity , R
colour scale, Iodine color number, European Pharmacopoeia, US Pharmacopeia, 8
degree gloss value (CM-3600A, CM-3610A, CM-3600d, CM-2600d/2500d, CM-
700d/600d only) , user equation , each difference, 555
Note on Haze (ASTM D1003-97):
With some instrument types, the illumination/observation system may not satisfy the
definition of haze (ASTM D1003-97). However, this presents no problem as long as
the value is used as a relative value.
ΔE*
(CIE 1976), ΔE*
Color
ab
and hue, ΔE
difference
equation
(DIN99), ΔE (Hunter), CMC (I:c)
hue, FMC-2 , NBS 100 , NBS 200 , ΔEc (degree) (DIN 6175-2) , ΔEp
(degree) (DIN 6175-2)
Index
Strength , Pseudo Strength , Staining degree (ISO 105.A04E) , Staining degree
Difference
rating (ISO 105.A04E) , Grey scale (ISO 105.A05) , Grey Scale Rating (ISO
105.A05) , K/S strength (Apparent (ΔE*
absorption, total wavelength, user wavelength) , NC# , NC# Grade , Ns , Ns
Grade
Notes concerning displayed values:
The SpectraMagic NX software enhances calculation accuracy by performing inter-
nal calculations with numbers greater in magnitude than those actually displayed.
Consequently, the least significant digit displayed may differ from that of the instru-
ment by one digit due to rounding or color space conversion.
Because the tolerance judgement calculation and graph-plotted points are also pro-
cessed with numbers greater in magnitude than those actually displayed, the judge-
ment result or plotted points may differ from those obtained with the values
displayed on the instrument.
Each colorimetric value of the data measured with a spectrophotometer or obtained
by manual input of spectral reflectance data is calculated from spectral reflectance.
Each colorimetric value of the data measured with a colorimeter or obtained by man-
ual input of colorimetric data is calculated from XYZ data. As a result, the colorimet-
ric value of the average value obtained by the manual averaging measurement or by
the averaging of list data may differ from the average of colorimetric values dis-
played in the list.
Observer
2 degree , 10 degree
, LCh
, XYZ , Hunter Lab, Yxy , L*u'v' , L*u*v* ,
99
99
), Haze (ASTM D1003-97 ), Density (Status A , Status T ),
(CIE 1994)
94
(CIE 2000) and each component of lightness, saturation and hue, ΔE
00
C
HAPTER
R
R
, Gardner, Hazen (APHA)
X
Y
Z
and each component of lightness, saturation
and each component of lightness, saturation and
, ΔL*, ΔC*, ΔH*, Δa*, Δb*) maximum
ab
1 : O
VERVIEW
99
E7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents