LED indication

Three LED on the Built-In AIT's front side signal the status of the drive and the AIT data
cartridge.
LED
TAPE MOTION
OFF
No data cartridge set.
ON
Data cartridge set.
Blink (Slow)
Set data cartridge
operating normally
(Write/Read).
Blink (Fast)
Set data cartridge
operating normally
(Other than Write/Read).
All LED:
Malfunction
Blink (Fast)
Blink (Fast)
: 0.3 s ON, 0.3 s OFF
Blink (Slowly)
: 0.9 s ON, 0.3 s OFF

Reading/writing data

To read/write the data from/to the AIT data cartridge, see the instruction manual provided with the
backup application.

Cleaning

To keep the drive in good condition, regular cleaning is required.

Cleaning the read/write head

When the CLEANING REQUEST LED lights, clean the Built-In AIT internal read/write head.
Set the provided cleaning cartridge in the drive, following the procedure described in "Handling"
in "Setting the AIT Data Cartridge".
When set in the Built-In AIT, the cleaning cartridge automatically starts cleaning the head.
After cleaning, the cleaning cartridge is automatically ejected (which requires about 35 seconds
after starting cleaning). Remove the cleaning cartridge.
CLEANING REQUEST
Built-In AIT does not
need cleaning.
Built-In AIT needs
cleaning.
Cleaning head or
cleaning cartridge tape
ended.
-
REPLACE TAPE
No data cartridge error.
Data cartridge error.
-
-
Built-in AIT 101