Page 1
Order No: APIN1504003CE Service Manual MODELS: CW-UC1815AF CW-UC2415AF Destination OMAN IMPORTANT SAFETY NOTICE There are special components used in this equipment which are important for safety. These parts are marked by the Schematic Diagrams, Circuit Board Diagrams, Exploded Views and Replacement Parts List. It is essential that these critical parts should be replaced with manufacturer’s specified parts to prevent shock, fire or other hazards.
SAFETY PRECAUTIONS Please observe these following safety precautions when using your air conditioner. Failure or negligence in observing these safety precautions could cause fire, electrical shock or personal injury. This sign warns of risk of death or serious injury. WARNING This sign warns of risk of injury or damage to property.
HOW TO INSTALL Remove the cabinet screws. Depending upon the location of the AC outlet, route the AC cord to either the Slide the chassis out from the cabinet. left or right side while installing the front grille. This figure shows the AC cord routed to the left side. Place cabinet into the installation hole.
HOW TO INSTALL DRAIN WATER T o achieve maximum cooling efficiency, the airconditioner is designed to splash the condensation water on the condenser coil. Screws In order to avoid the splashing sound, an external drain can be Drain Pan provided by using the following procedure. This may however cause a small loss of performance.