Error
Code
Error Contents and Cause
(SD0)
• In the operating mode of a multiple
CPU system, a CPU error occurred at
the CPU where "All station stop by
stop error of CPU " was selected.
• In a multiple CPU system, a CPU
module incompatible with the multiple
7000
CPU system was mounted.
In a multiple CPU system, CPU other
than CPU No.1 cannot be started up
due to stop error of the CPU No.1 at
power-on, which occurs to CPU No.2 to
No.4.
• There is no response from the target
CPU module in a multiple CPU
system during initial communication.
• In a multiple CPU system, a CPU
module incompatible with the multiple
CPU system was mounted.
7002
• There is no response from the target
CPU module in a multiple CPU
system during initial communication.
There is no response from the target
7003
CPU module in a multiple CPU system
at initial communication stage.
*3
The Universal model QCPU except the Q02UCPU.
Corrective Action
• Read the individual information of the
error using the GX Developer, check
the error of the PLC resulting in CPU
module fault, and remove the error.
• Remove the CPU module
incompatible with the multiple CPU
system from the main base unit.
Read the individual information of the
error using the GX Developer, check the
error of the PLC resulting in CPU
module fault, and remove the error.
• Reset the CPU module and RUN it
again. If the same error is displayed
again, this suggests the hardware
fault of any of the CPU modules.
(Contact your local Mitsubishi
representative.)
• Remove the CPU module
incompatible with the multiple CPU
system from the main base unit. Or,
replace the CPU module
incompatible with the multiple CPU
system with the compatible one.
• Reset the CPU module and RUN it
again. If the same error is displayed
again, this suggests the hardware
fault of any of the CPU modules.
(Contact your local Mitsubishi
representative.)
Reset the CPU module and RUN it
again. If the same error is displayed
again, this suggests the hardware fault
of any of the CPU modules. (Contact
your local Mitsubishi representative.)
246
Corresponding
CPU
*1
Q00/Q01
*1
Qn(H)
QnPH
QnU
*1
Q00/Q01
*1
Qn(H)
QnPH
QnU
*1
Q00/Q01
*1
Qn(H)
QnPH
QnU
*1
Q00/Q01
*1
Qn(H)
QnPH

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec q4arcpu-u(h/w)-e13j851

Table of Contents