Page 7
MT6250 User’s Manual V1.3 Vertical 30° Pitch Angle ±60° Skew Angle ±50° Roll Angle 360° Print Contrast Ratio Width of Field 141mm (13Mil Code39) 3 Mil Code 39: 61 ~ 110mm 5 Mil Code 39 : 35 ~ 178mm Typical D.O.F...
MT6250 User’s Manual V1.3 Pin Definition USB Connection (MT6250U) USB (Type A Male): Pin Signal +5VCC Data - Data + RS232 Connection (MT6250R) RS232 (D-Sub 9 Female): Pin Signal TXD(Out) RXD(In) CTS(In) RTS(Out) +5VCC Note: Power can be supplied either directly to Pin 9 from the host or to DC Jack from power adapter (5V,...
MT6250 User’s Manual V1.3 Chapter 2 General Settings Barcode Configurability Scanning below configuration barcodes will allow/prohibit user to change settings by scanning configuration barcodes in this manual. Enable Barcode Configurability* Disable Barcode Configurability Factory Default Scanning below configuration barcode will reset all parameters to factory default settings (the ones...
MT6250 User’s Manual V1.3 Good Read Indicator Beep Tone Beep Low (2.0KHz) Beep Medium (2.7KHz)* Beep High (4.0KHz) Indicator LED Data Format UTF-8 to Unicode Conversion Off*...
MT6250 User’s Manual V1.3 HT/CR/ESC Converts to TAB/ENTER/ESCAPE Off* Note: 1. By default, HT [$I], CR [$M] and ESC [%A] is transmitted as <0x09>, <0x0D> and <0x1B> respectively. 2. When enabled, HT [$I], CR [$M] and ESC [%A] is transmitted as <TAB>, <ENTER> and <ESCAPE>...
MT6250 User’s Manual V1.3 Control Code Output Method Ctrl Mode* Alt Mode Disable Output Note: Control code (0x01 ~ 0x1A) can be sent by two methods: (1) Ctrl Mode: A barcode of “A<HT>F” (0x41/0x09/0x46) is scanned, the output sequence is: a.
MT6250 User’s Manual V1.3 Numeric Key Numeric Key Alphanumeric Key* Note: 1. By default, the alphanumeric key is used for trasmitting digits. Scan NUMERIC KEY if you want to use the keys on the numeric keypad. 2. If you select NUMERIC KEY, the Num Lock status of the physical keyboard should be ON.
MT6250 User’s Manual V1.3 Capslock Free Note: When barcode scanner is set to Capslock Free mode, no matter keyboard Capslock LED indicator is ON or OFF, output will be always the same as the Original barcode. In other words, what you see is what output is.
MT6250 User’s Manual V1.3 Chapter 3 Interface USB HID Scanning below configuration barcode will set MT6250U (USB cable) to USB HID interface, in which the scanner becomes an HID keyboard device. Do not scan below configuration barcode with MT6250R (RS232 cable).
Page 18
MT6250 User’s Manual V1.3 Italian French German Swiss German Swiss French Swedish Czech (QWERTZ) Czech (QWERTY) Norwegian Belgian Portuguese Slovak Brazilian (QWERTY) Canadian (Traditional)
MT6250 User’s Manual V1.3 Japanese Alt Code Intercharacter Delay The configurable range is from 0 to 255ms, with 1ms increment. The larger the number, the longer the delay. Set Intercharacter Delay (Default = 0ms) Example: Set Intercharacter Delay to 8ms Step1: Scan Set Intercharacter Delay Step2: Scan “0”...
MT6250 User’s Manual V1.3 Step2: Scan “0” “0” “2” in Appendix - Numbers Step3: Scan Set Interblock Delay USB VCP Scanning below configuration barcode will configure MT6250U (USB cable) to USB VCP interface. The scanner will be able communicate with the host via USB Virtual COM. Normally virtual COM port can be recognized by the host.
MT6250 User’s Manual V1.3 Chapter 4 Reading Mode Imager Auto-sensing Mode In Imager Auto-sensing Mode, the scanner starts scanning whenever any change of image is detected. Imager Auto-sensing Mode* Infrared Auto-sensing Mode In Infrared Auto-sensing Mode, the scanner starts scanning whene an object is detected within the Infrared Auto-sensing Range.
Page 25
MT6250 User’s Manual V1.3 Note: 1. Near = approx. 13cm auto-sensing range 2. Middle = approx. 20cm auto-sensing range (Default) 3. Far = approx. 27cm auto-sensing range 4. Auto-sensing range may vary depending on the surface reflectiveness of the object. Above...
MT6250 User’s Manual V1.3 Chapter 5 Data Format By default data format is as follows: <Preamble> <Code ID> <Barcode Length> <Barcode Data> <Postamble> <Terminator> Code ID When Factory ID is enabled, a Factory ID (see Appendix – Factory ID) will be added to the beginning of each barcode data.
Page 27
MT6250 User’s Manual V1.3 Set ID – Code128 Set ID – EAN-13 Set ID – EAN-8 Set ID – UPC-A Set ID – UPC-E0 Set ID – Interleaved 2 of 5 Set ID – Matrix 2 of 5 Set ID – Industrial 2 of 5 Set ID –...
MT6250 User’s Manual V1.3 Set ID – QR Code Set ID – Data Matrix Set ID – Aztec Set ID – MaxiCode Example: Set Code39 Set ID as XY" Step1: Scan “Set ID – Code39” Step2: Scan “X” “Y” in Appendix - Upper Case Alphabets Step3: Scan “Set ID –...
MT6250 User’s Manual V1.3 Step 2: Scan “X” “Y” “Z” “1” “2” “3” in Appendix - Upper Case Alphabets & Numbers Step 3: Scan “Set Preamble” Postamble Postamble can be up to 16 bytes of data. Set Postamble Example: Set XYZ123 as Postamble Step 1: Scan “Set Postamble”...
MT6250 User’s Manual V1.3 Note: When all symbologies are disabled, configuration barcodes are still readable. UPC-A Enable/Disable UPC-A Enable UPC-A* Disable UPC-A Check Digit Send Check Digit* Not Send Check Digit UPC-A to EAN-13 Enable UPC-A to EAN-13 Disable UPC-A to EAN-13*...
MT6250 User’s Manual V1.3 Code128/GS1-128 Min/Max Length Set Min Length Set Max Length (Default = 04) (Default = 50) Example: Set Min Length as 8, Max Length as 12 for Code128/GS1-128 Step1: Scan “Set Min Length” Step2: Scan “0” “8” in Appendix - Numbers Step3: Scan “Set Min Length”...
MT6250 User’s Manual V1.3 Full ASCII Code39 Enable Full ASCII Code39* Disable Full ASCII Code39 Code39 Min/Max Length Set Min Length Set Max Length (Default = 01) (Default = 50) Example: Set Min Length as 8, Max Length as 12 for Code39 Step1: Scan “Set Min Length”...
MT6250 User’s Manual V1.3 Code 32 Enable/Disable Code 32 Enable Code 32 Disable Code 32* Notw: Please make sure Code39 is enabled with verification disabled before enabling Code32. Leading/Tailing Not Send Leading & Tailing Send Leading Only Send Tailing Only...
MT6250 User’s Manual V1.3 Code 93 Enable/Disable Code 93 Enable Code 93* Disable Code 93 Code 93 Min/Max Length Set Min Length Set Max Length (Default = 04) (Default = 50) Example: Set Min Length as 8, Max Length as 12 for Code93 Step1: Scan “Set Min Length”...
MT6250 User’s Manual V1.3 Code 11 Min/Max Length Set Min Length Set Max Length (Default = 04) (Default = 50) Example: Set Min Length as 8, Max Length as 12 for Code11 Step1: Scan “Set Min Length” Step2: Scan “0” “8” in Appendix - Numbers Step3: Scan “Set Min Length”...
MT6250 User’s Manual V1.3 Codabar (NW-7) Enable/Disable Codabar Enable Codabar* Disable Codabar Start/Stop Send Start/Stop Not Send Start/Stop* Codabar Min/Max Length Set Min Length Set Max Length (Default = 04) (Default = 50) Example: Set Min Length as 8, Max Length as 12 for Codabar Step1: Scan “Set Min Length”...
MT6250 User’s Manual V1.3 Interleaved 2 of 5 Min/Max Length Set Min Length Set Max Length (Default = 05) (Default = 50) Example: Set Min Length as 8, Max Length as 12 for Interleaved 2 of 5 Step1: Scan “Set Min Length”...
MT6250 User’s Manual V1.3 Matrix 2 of 5 Enable Disable Matrix 2 of 5 Enable Matrix 2 of 5* Disable Matrix 2 of 5 Matrix2 of 5 Min/Max Length Set Min Length Set Max Length (Default = 04) (Default = 24) Example: Set Min Length as 8, Max Length as 12 for Matrix 2 of 5 Step1: Scan “Set Min Length”...
MT6250 User’s Manual V1.3 Industrial 2 of 5 Enable/Disable Industrial 2 of 5 Enable Industrial 2 of 5* Disable Industrial 2 of 5 Industrial 2 of 5 Min/Max Length Set Min Length Set Max Length (Default = 04) (Default = 24) Example: Set Min Length as 8, Max Length as 12 for Industrial 2 of 5 Step1: Scan “Set Min Length”...
MT6250 User’s Manual V1.3 MSI Plessey Min/Max Length Set Min Length Set Max Length (Default = 04) (Default = 50) Example: Set Min Length as 8, Max Length as 12 for MSI Plessey Step1: Scan “Set Min Length” Step2: Scan “0” “8” in Appendix - Numbers Step3: Scan “Set Min Length”...
MT6250 User’s Manual V1.3 QR Code Enable/Disable QR Code Enable QR Code* Disable QR Code Micro QR Code Enable/Disable Micro QR Code Enable Micro QR Code* Disable Micro QR Code Data Matrix Enable/Disable Data Matrix Enable Data Matrix* Disable Data Matrix...
MT6250 User’s Manual V1.3 Appendix – Modifier Keys Alt (Left) make *1 Alt (Left) break Alt (Right) make Alt (Right) break Shift (Left) make *2 Shift (Left) break Shift (Right) make Shift (Right) break Win (Left) make Win (Left) break...
MT6250 User’s Manual V1.3 Appendix - Default Table Function Default Remark General Settings Barcode Configurability Beep Tone Medium (2.7KHz) Indicator LED Data Format UTF-8 to Unicode Conversion HT/CR/ESC Converts to TAB/ENTER/ESCAPE Function Code Conversion Control Code Output Method Ctrl Mode...
Page 70
MT6250 User’s Manual V1.3 Set ID Data Length Preamble Postamble Terminator Symbologies General Settings UPC-A Enable/Disable Check Digit Send UPC-A to EAN-13 UPC-E0 Enable/Disable Check Digit Send UPC-E0 to UPC-A EAN-8 Enable/Disable Check Digit Send EAN-13 Enable/Disable Check Digit Send...
Page 71
MT6250 User’s Manual V1.3 Code 93 Enable/Disable Min Length Max Length Code 11 Enable/Disable Verification Disable CDV Check Digit Not Send Min Length Max Length Codabar Enable/Disable Start/Stop Not Send Min Length Max Length Interleaved 2 of 5 Enable/Disable Verification...
Page 72
MT6250 User’s Manual V1.3 Enable/Disable QR Code Enable/Disable Micro QR Code Enable/Disable Data Matrix Enable/Disable PDF417 Enable/Disable MicroPDF417 Enable/Disable Aztec Enable/Disable MaxiCode Enable/Disable...