Replacing the Switch Fabric Board on the SRX3600 Services Gateway
Tighten the screws on either side of the card.
12.
Reconnect the cables, if any, that you disconnected from the SFB front panel
13.
connectors in Step 4.
Figure 2: Inserting the SFB
Ejector levers
Power on the services gateway by pressing the Power button on the front panel
14.
of the SFB for three to five seconds. Wait for the device to start.
Verify that the SFB is functioning normally by checking the LEDs on its faceplate.
15.
The SFB STATUS LED should light steadily green a few minutes after the device
is powered on. If the SFB STATUS LED is red, remove and install the SFB again.
If the SFB STATUS LED still lights steadily red, the SFB is not functioning properly.
Contact your customer support representative.
To check the status of the SFB:
user@host> show chassis environment fpc 0
CB 0 status:
State
Temperature
Power 1
1.2 V
1.5 V
1.8 V
2.5 V
3.3 V
5.0 V
12.0 V
1.25 V
3.3 V SM3
5.0 V RE
12.0 V RE
Power 2
11.3 V bias PEM
11.3 V bias FPD
11.3 V bias POE 0
11.3 V bias POE 1
Bus Revision
FPGA Revision
Captive screw
Online Master
30 degrees C / 86 degrees F
1202 mV
1511 mV
1798 mV
2481 mV
3306 mV
4956 mV
12084 mV
1250 mV
3287 mV
5046 mV
11910 mV
11292 mV
11156 mV
11253 mV
11272 mV
42