Accidental restart preventive
function
If you install the battery cartridge while pulling the
switch trigger, the tool does not start. To start the tool,
release the switch trigger, and then pull the switch trig-
ger again while depressing the lock-off button.

Electronic function

The tool is equipped with the following electronic func-
tions for easy operation.
Electric brake
The tool is equipped with an electric brake. If the tool
consistently fails to quickly stop after releasing the
switch trigger, have the tool serviced at your local
Makita Service Center.
Soft start feature
The soft-start function minimizes start-up shock, and
makes the tool start smoothly.
ASSEMBLY
CAUTION:
Always be sure that the tool is
switched off and the battery cartridge is removed
before carrying out any work on the tool.
Box wrench storage
When not in use, store the box wrench as shown in the
figure to keep it from being lost.
1
Fig.6
► 1 . Box wrench
Removing and installing planer
blades
CAUTION:
Tighten the blade installation bolts
carefully when attaching the planer blades to
the tool. Always check to see they are tightened
securely. A loose installation bolt can be dangerous.
CAUTION:
Handle the planer blades very
carefully. Use gloves or rags to protect your fin-
gers or hands when removing and installing the
planer blades.
CAUTION:
Use only the Makita wrench pro-
vided to remove and install the planer blades.
Failure to do so may result in overtightening or insuf-
ficient tightening of the installation bolts. This could
cause an injury.
NOTICE:
To install planer blades, clean out all
chips or foreign matter adhering to the drum or
the planer blades. Use planer blades of the same
dimensions and weight, otherwise drum oscilla-
tion/vibration, causing poor planing action, and
tool breakdown will result.
For tool with conventional planer
blades
NOTE: A pair of planer blades are assembled in
the drum. Repeat the following procedures for each
planer blade.
Removing conventional planer blades
1.
Unscrew the installation bolts from the drum using
the box wrench provided.
2.
Disassemble the drum plate and conventional
planer blade (with adjusting plate) from the drum.
Fig.7
► 1 . Installation bolt 2. Drum plate 3. Conventional
planer blade (with adjusting plate) 4. Drum
8 ENGLISH
1
2
3
4