Drain Quench Assembly - Jackson Enodis AJ-54 Series Installation/Operation & Technical Manual

Rack conveyor dishmachine
Table of Contents

Advertisement

Reducer, 1-1/2" x 1/4"
04730-002-55-76
To Dishmachine Drain
Nipple, 1-1/2" NPT
04730-207-40-00
Tee, 1-1/2" x 1-1/2" x 1-1/2"
04730-011-69-93
From the existing drain, attach the two additional Tees (Item 7) using the 1-1/2" NPT Close Nipples (Item 8). Tighten the
Reducers (Items 6 & 9) into the Tees as shown above. Attach the Modified Compression Fitting (Item 10) into the 1-1/2" to 1/4"
Reducer (Item 9). Position the bulb of the thermostat (Item 1) so that it rests approximately 1/4" from the bottom of the Tee (Item
7). Tighten the Modified Compression Fitting (Item 10) as required.
Mount the Thermostat (Item 1) to the tub using the Thermostat Bracket (Item 2) and set it for 120°F - 140°F. Install the Solenoid
Valve (Item 3) to the second Tee (Item 7) and then attach to the incoming cold water line. Use pipe dope or thread tape as
required to prevent any leaks.
SECTION 6: PARTS SECTION
DRAIN QUENCH SYSTEM
Modified Compression
Fitting
05700-001-16-52
AJ-54C Series Technical Manual 7610-002-30-91
Issued: 03-22-2006 Revised: N/A

Drain Quench Assembly

To Cold Water Supply
To Drain
Reducer, 1-1/2" to 1/2"
04730-002-55-75
92
06401-002-44-07
Thermostat
05930-121-67-72
Thermostat Bracket
05700-002-73-72
Solenoid Valve
04810-100-09-18
Nipple, Close, 1/2" NPT
04730-207-15-00
Valve, Check, 1/2"
04820-002-55-77

Advertisement

Table of Contents
loading

Table of Contents