Operating Characteristics - Jackson Enodis AJ-54 Series Installation/Operation & Technical Manual

Rack conveyor dishmachine
Table of Contents

Advertisement

RACKS PER HOUR:
AJ-54-76-90CE/CS/CGP
DISHES OR GLASSES PER HOUR:
AJ-54-76-90CE/CS/CGP
PREWASH TANK CAPACITY (GALLONS):
AJ-76CE/CS/CGP
AJ-90CE/CS/CGP
WASH TANK CAPACITY (GALLONS):
AJ-54-76-90CE/CS/CGP
PREWASH PUMP CAPACITY (GPM):
AJ-76CE/CS/CGP
AJ-90CE/CS/CGP
WASH PUMP CAPACITY
GALLONS PER MINUTE (ALL MODELS):
VENTING REQUIREMENTS (CFM)(100% CAP.):
INPUT END
OUTPUT END
TOTAL
CONVEYOR SPEED (FPM):
AJ-54-76-90CE/CS/CGP MACHINES
GALLONS PER RACK:
AJ-54-76-90CE/CS/CGP MACHINES
WATER TEMPERATURES:
AJ-54-76-90CE/CS/CGP MODELS:
PREWASH (RECOMMENDED) (AJ-76/AJ-90)
WASH (MINIMUM)
RINSE (MINIMUM)
FLOW PRESSURE (PSI)
FLOWRATE (GPM):
AJ-54-76-90CE/CS/CGP
SECTION 1: SPECIFICATION INFORMATION

OPERATING CHARACTERISTICS

270
6750
16
16
20.4
120
270
270
200
400
600
7.5
1.03
110-140°F
160°F
180°F
20±5
4.7
AJ-54C Series Technical Manual 7610-002-30-91
Issued: 03-22-2006 Revised: N/A
STEAM COIL TANK HEAT (CS/CSL MODELS ONLY):
STEAM INLET PRESSURE (PSIG)
STEAM CONNECTION NPT
CONSUMPTION @ 15 PSIG (lbs/hr):
AJ-54-76-90CS/CSL
MOTOR ELECTRICAL CHARACTERISTICS:
DRIVE MOTOR HP
WASH MOTOR HP
POWER RINSE MOTOR HP
PREWASH MOTOR HP:
AJ-76 MODELS
AJ-90 MODELS
NOTE: Typical Electrical Circuit is based upon (1) 125% of
the full amperage load of the machine and (2) typical
fixed-trip circuit breaker sizes as listed in the NEC 2002
Edition. Local codes may require more stringent protec-
tion than what is displayed here. Always verify with your
electrical service contractor that your circuit protection is
adequate and meets all applicable national and local
codes. These numbers are provided in this manual sim-
ply for reference and may change without notice at any
given time.
2
10-20
3/4"
60
1/4
2
2
1
2

Advertisement