- Medium: use Medium sensitivity if your application has varying
document thickness or labels attached to the document.
Depending on the label material, most documents with labels
should not be detected as a multifed document.
- High: the most aggressive setting. This is a good setting to use if
all documents are similar in thickness to 75.2 g/m
paper.
Active Sensors — three sensors cover the width of the paper path. In
order for multifed documents to be detected correctly, they must pass
under one of these sensors.
• Left, Center, Right: this allows you to select which sensor(s) you
want to have turned on. For example, if you know that the left side of
the document has a "sticky" note on it, you can turn off the left sensor.
• Action — select what action you want the scanner to take when a
multifeed is detected. With all options, the condition will be logged in
the scanner.
- Stop Scanning: scanning will stop and control will return to the
scanning application (i.e., ends the job). Verify that the paper path
has been cleared and restart the scan session from the scanning
application.
- Stop Scanning - leave paper in path: scanning will stop
immediately (i.e., making no attempt to clear the paper path) and
control will return to the scanning application (i.e., ends the job).
Clear any documents from the paper path prior to restarting the
scan session from the scanning application.
- Continue Scanning: the scanner will continue to scan.
- Pause Scanning: scanning will stop but the scanning application
will be waiting for additional images (i.e., stops the feeder).
Scanning may be resumed by pressing the Start/Resume button
on the scanner. Scanning may be stopped by pressing the Stop/
Pause button on the scanner or via the scanning application.
- Pause Scanning - leave paper in path: scanning will stop
immediately (i.e., making no attempt to clear the paper path) but
the scanning application will be waiting for additional images (i.e.,
stops the feeder). Clear any documents from the paper path prior
to resuming the scan session. Scanning may be resumed by
pressing the Start/Resume button on the scanner. Scanning may
be stopped by pressing the Stop/Pause button on the scanner or
via the scanning application.
Alarm Volume — select Low, Medium or High if you want the scanner
to make a sound when a multifeed is detected.
NOTE: Clicking the Speaker icon will display the Open dialog box
allowing you to select the desired tone (.wav file) for your alarm.
Calibrate — displays the Calibration window allowing you to perform
an Image Chain or UDDS calibration.
NOTE: Frequent calibration is not necessary or recommended. Only
perform a calibration when instructed to do so by your support
personnel.