INSTALLING THE HHFAN100 BLOWER (OPTIONAL)
WARNING
your protection against shock hazard and should be plugged directly
into a properly grounded three-prong receptacle (See Fig. 5).
Disconnect heater from the gas supply before installing the fan
accessory. Contact a qualified service person to do this.
1. Remove the blower panel using a screwdriver (see Fig. 6).
2. Attach blower duct to the rear panel of the heater using four
screws provided (see Fig. 7).
3.
Attach blower thermal switch bracket to blower panel
with two screws provided. Note the bracket attaches to
the upper set of holes (see Fig. 8.
Installation (cont.)
Electrical grounding instructions: This appliance is
equipped with a three-prong (grounding) plug for
Fig. 8—Attaching Thermal Switch Bracket
Use upper set of holes
14
Vent-Free Gas Stove User's Manual
Fig. 5—Grounded
Three-Prong Receptacle
Fig. 6—Remove Blower Panel