Siemens SIMATIC S7-1500 Manual page 38

Hide thumbs Also See for SIMATIC S7-1500:
Table of Contents

Advertisement

Meaning of the STOP ACTIVE LED
The following table shows the meaning of the STOP ACTIVE LED for the CPU 1511-1 PN.
Table 4- 3
Meaning of the LEDs
STOP ACTIVE LED
LED lit yellow
LED off
CPU 1511-1 PN (6ES7511-1AK02-0AB0)
Equipment Manual, 05/2021, A5E40869673-AB
The CPU is switched to "STOP" mode using the STOP button.
As long as the STOP ACTIVE LED is lit up, switching the CPU to RUN mode is only possible
using the RUN button.
The CPU can then no longer be set to RUN mode via the display operation or via online func-
tions. The state of the buttons is retained at power-off. If the CPU does not start up auto-
matically after a power-on, you have to keep the STOP button pressed during start-up until
the STOP ACTIVE LED is activated.
If an automatic start-up is to be reliably prevented after a power-up, the STOP button has to
be kept pressed during the start-up of the CPU until the STOP ACTIVE LED is activated.
The CPU is set to "STOP" mode using the display or programming device and not with the
STOP button on the device.
The CPU is in RUN mode.
Interrupts, error messages, diagnostics and system alarms
4.1 Status and error display of the CPU
Meaning
37