Maintenance; Preventive Maintenance Schedule - Atlas Copco LE5 Instruction Book

Piston compressors
Hide thumbs Also See for LE5:
Table of Contents

Advertisement

4 Maintenance

4.1 Preventive maintenance schedule

The schedule contains a summary of the maintenance instructions.
Read the respective section before taking maintenance measures.
When servicing, replace all disengaged packings, e.g. gaskets,
Period 1)
Running
Operation
hours 1)
Daily
------
Check oil level (not on LEN)
Drain condensate from air receiver by opening drain cock (10-Figs. 1)
Weekly
------
Monthly
------
Operate safety valve by turning its knurled cap or by lifting its central
plunger with a screwdriver
"
------
Check that regulating system operates properly
"
------
Inspect air filter. Replace if necessary
3-monthly
------
Clean unit. Remove dirt from cooling fins by air jet
Yearly
------
Test safety valve
"
------
If provided, test relief valve
"
400
On LE/LT9/12, replace air filter
"
500
On LE/LT7/8, replace air filter
"
700
On LE/LT5/6, replace air filter
"
1000
Change muffler element on LE/LT7 up to -12 and LEN
"
1000
Check tension of transmission belt(s) (if equipped with)
"
2000
Change oil if mineral oil is used (not on LEN)
Inspect for carbon deposits in air receiver; clean if necessary
"
2000
2-yearly
3000
Change oil if Atlas Copco approved P.A.O. oil is used (not on LEN)
-----
3000 to
Change check valve on LE/LT5/6 or unloader
4000
on LE/LT7 up to -12 and LEN
-----
4000
Change valves. For possible earlier replacement consult section 5.2
1) Whichever interval comes first . The local Sales Company may overrule the maintenance schedule, especially the service
intervals, depending upon the environmental and working conditions of the compressor.
Remark
For partial or complete overhaul, service kits, exchange compressors, etc. are available. Consult Atlas Copco.
Notes
1. Maintain the level in the lower half of the sight-glass.
2. Always wear gloves.
3. Wear safety glasses.
4. For normal operation in clean surroundings. More frequently when operating in dusty environment.
5. Correct adjustment is obtained when each V-belt can be pushed inwards 15 mm per m distance between the two pulley centres when
a force of 20 N is exerted midway.
2920 5997 03
O-rings, washers. Consult Atlas Copco for available maintenance
kits.
The "longer interval" checks must also include the "shorter
interval" checks.
Industrial Air Division
Consult
See
Preventive
section
note
main-
tenance
kit No.
3.2
1
--
--
--
--
--
2
--
--
--
--
5.3
4
2-Fig. 4
--
3
--
5.5
--
--
5.6
--
--
5.3
4
2-Fig. 4
5.3
4
2-Fig. 4
5.3
4
2-Fig. 4
--
--
2-Fig. 4
--
5
--
4.2
--
--
--
--
--
4.2
--
5-Fig. 4
5.1
--
3,4-Fig. 4
5.2
--
1-Fig. 4
9

Hide quick links: