11
FACILITY REQUIREMENTS POSTER - COMPACT INSTALLATION
Argon Gas
Bulk Argon tank
1
▪ Option for high argon demand sites
Argon cylinders
2
▪ Use a high volume pressure reducer
▪ Connect cylinders with auto-switching
manifold to ensure constant argon
supply during build
Compressed Air
A/C
Air Conditioning
• Required
Do not install vent directly above process station!
Atmosphere
max
27° C (80° F)
min 16° C (60° F)
Room temperature
setpoint and stability
• Set temperature between 18° C and 24° C (65° F and 75° F)
• Temperature should be constant to ±2° C (± 5° F)
Coolant Hoses
▪ Included with 3D Systems-supplied chiller
▪ 1/2" barbed hose fitting
CHILLER
Chiller power
Separate from
DMP Flex 350
• 200 to 230 VAC
• 50/60 Hz
• 15 kVA
• C
ustomer supplied/installed
Argon
• Customer supplied/installed
Compressed air
• Customer supplied/installed
Electrical cable
• Customer supplied/installed
Transformer
(optional)
Control cabinet
power panel
• 400 VAC
• 50/60 Hz
• 10 kVA
Room oxygen monitor
• Recommended
• Customer supplied/installed