EVAL-M1-IM818-A user guide
Evaluation power board with MADK M1 connector
System and functional description
2.3

Setting up the system

After downloading and installing the iMOTION™ PC Tools (MCEWizard and MCEDesigner), the following steps
needs to be executed in order to run the motor. Refer to user manual for iMOTION™ MADK control board such
as (EVAL-M1-101T), MCEWizard and MCEDesigner documentation for more information.
Figure 3 shows the system connection using EVAL-M1-IM818-A and control board (used control board EVAL-M1-
101T for example).
Setting step:
1. Connect PC-USB connector on the on-board-debugger to the PC via USB cable.
2. Connect EVAL-M1-IM818-A's MADK M1 20-pin interface connector (J3) to control board (see figure 3).
3. Get the latest "IMC101T-T038 MCE Software Package" available on
web page. (Infineon iMOTION™ control IC IMC101T-T038 is used for control board EVAL-M1-101T).
4. Connect motor phase outputs to the motor.
5. Use MCEWizard to enter the motor and evaluation board hardware parameters and click button "Export to
Designer file (.txt)" to system drive parameters file which will be used by MCEDesigner.
6. Connect AC power to power input connector (J1) and power on system.
7. Open MCEDesigner and open MCEDesigner default configuration file (.irc) for IMC101T devices
(IMC101T_xx.irc) by clicking "File" menu and select "Open" in the pull-down list.
8. Import system drive parameters file (generated in step 5) into MCEDesigner by clicking "File" > "Import Drive
Parameters". Select "Update All" radio button.
9. Program the MCE Firmware and system parameters into the internal Flash memory of iMOTION™ IC by
clicking "Tools > Programmer "in the pull-down menu, and then clicking on the "Program Firmware and
Parameter" radio button. See chapter MCEDesigner setup overview section 2.4 for more details. If the latest
version of MCE firmware is already programmed into the IMC101T-T038 IC, then programming firmware can
be skipped by selecting "Program Parameters" radio button option. Finally click "Start" button to program
firmware and parameter (or parameters only when programming firmware was skipped).
10. Start the motor by clicking the green traffic light button in the control bar.
2.4
iMOTIOM
The iMOTION™ Development Tool installers for MCEDesigner and MCEWizard are available for download via
Infineon iMOTION
website (http://www.infineon.com/imotion-software). All the available tools and software
TM
variants are listed there.
On-board debugger uses the SEGGER J-Link's driver for UART communication with IMC101T-T038. J-Link driver
will be installed during the MCEDesigner installation. In case the driver is not installed properly, please go to
SEGGER J-Link website
Windows".
User guide
development tools and software
TM
to download and install the latest J-Link "Software and Documentation pack for
www.infineon.com/imotion-software
10 of 35
Revision 1.4
2021-09-10

Advertisement

Table of Contents
loading

Table of Contents