Quick Start Guide for Cisco 910 Industrial Routers

Resetting to Factory Mode

4.
Configure the baud rate and character format of the PC or terminal to match these console port default
characteristics:
115200 bits per second
8 data bits
1 stop bit
No parity
None (flow control)
5.
Connect the power of the Cisco 910 Industrial Router to an AC/DC power adapter. The PC or terminal displays the
bootloader sequence.
6.
Press Enter to display the setup prompt.
Resetting to Factory Mode
To reboot the entire system, press the Reset button and release it immediately. To revert to the factory mode, press and
hold the Reset button for more than 5 seconds.

FCC Class A Notices and Warnings

Statement 2017—Class A Notice for FCC
Modifying the equipment without Cisco's authorization may result in the equipment no longer complying with FCC
requirements for Class A digital devices. In that event, your right to use the equipment may be limited by FCC regulations,
and you may be required to correct any interference to radio or television communications at your own expense.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case
users will be required to correct the interference at their own expense.

RF Exposure Safety Notice

To comply with FCC/IC RF Exposure Limits set forth for an uncontrolled environment, the product must be installed and
operated with a minimum separation distance (between nearby person(s) and radiating antenna) according to the
following scenarios:
20cm minimum when the product is operated alone without co-transmitting with a plug-in 3G USB dongle device.
33cm minimum when the product is operated with a plug-in 3G USB device which has maximum of 7W ERP output
power.
For co-transmission scenario which is not covered above, please consult the RF technician or device supplier.