Power Vs. Ambient Temperature - Delta MOOVair User Manual

1 kw wireless charging system
Table of Contents

Advertisement

4.3.3

Power vs. ambient temperature

The maximum temperature the case of the WSB can reach is limited to ensure user safety. The charger
system will limit its output power when required so the maximum case temperature of 90 °C is not
exceeded. The graph below shows test results of the charger system attempting to provide full power
For example:
At 20 °C ambient the charger system can run continuously at full power
At 30 °C the charger system will run at full power for approximately 42 minutes and then eventually
reduce its output power to 930 W
Mounting the metal surface of the WSB to a heatsink or other large metal item such as an AGV chassis
will improve its thermal performance.
Volume of air surrounding the WSB
The ability of hot air to escape the vicinity of the WSB
The ability of cool air to enter the WSB installation
The proximity of the WSB to other hot components
Emissivity of surrounding materials
The WPU can run continuously at full power in an ambient temperature of up to 40°C.
required.
1000
950
900
850
800
20°C ambient
750
30°C ambient
700
40°C ambient
650
50°C ambient
600
0
10
20
30
to cool the charger system.
40
50
60
70
80
Time duration (min.)
90
100
110
11