Output Power And De-Rating; Output Operating Area; Power Vs. Input Voltage - Delta MOOVair User Manual

1 kw wireless charging system
Table of Contents

Advertisement

4.3

Output power and de-rating

4.3.1

Output operating area

The charger system can provide an output within the bounds of the graphs below.
Using the 48 V charger system as an example:
Between 24 V and 38 V the charger system can provide a maximum of 3 A
Between 38 V and 48 V the charger system can provide up to 20.8 A
Between 48 V and 60 V the charger system can provide a maximum of 1,000 W, and will
reduce the output current to achieve this
4.3.2

Power vs. input voltage

The charger system can operate from an AC supply of 85 to 265 V
less than 100 V
10
24 V operating area
48 V operating area
, the output power is automatically reduced to avoid the input current exceeding 13 A.
AC
48V operating area
. However when input voltage is
AC

Advertisement

Table of Contents
loading

Table of Contents