2.4 Limiting conditions
Maximum body designed conditions
PMA
Maximum allowable pressure
TMA
Maximum allowable temperature
PMO
Maximum operating pressure
TMO
Maximum operating temperature
Designed for a maximum cold hydraulic test pressure of:

2.5 Operating range

HM Series
300
200
100
0
0
The product must not be used in this region.
*PMO Maximum operating pressure recommended for saturated steam 14 bar g (203 bar g).
PMX - Maximum differential pressure
Size
½"
HM00/8
¾"
HM10/10
1"
HM12/12
DN15
HM003/8
DN20
HM103/10
DN25
HM123/12
Note: The pressure limit of the flange type should be greater than the pressure limit of the internal mechanism
selected.
10
Steam saturation curve
2
4
6
Pressure bar g
Maximum differential pressure bar
4
8.5
HM00/7
HM10/8
HM12/10
HM003/7
HM103/8
HM123/10
HM and HM34 Inverted Bucket Steam Traps
HM
PN16
16 bar g (232 psi g)
300 °C
16 bar g (232 psi g)
300 °C
24 bar g (348 psi g)
8
10
12
10
HM00/6
HM003/6
HM34
PN40
40 bar g (580 psi g)
(572 °F)
300 °C
40 bar g (580 psi g)
(572 °F)
300 °C
60 bar g (870 psi g)
14*
16
12.5
HM10/7
HM12/7
HM103/7
HM123/7
IM-S03-11 CMGT Issue 5
(572 °F)
(572 °F)
14