Fisher & Paykel SINGLE DISHDRAWER DD60SHI9 Installation Manual page 11

Integrated dishwasher
Hide thumbs Also See for SINGLE DISHDRAWER DD60SHI9:
Table of Contents

Advertisement

To prevent the build up of condensation produced by your DishDrawer™ Dishwasher, the external venting kit must be installed via one of the following options:
THROUGH SAME CABINET
FRAMELESS
5
Ø57
200
100
custom framed edge
ISO*
A toe kick height of at least 100mm is required.
z
A Ø57mm service hole should be created through
z
the side wall following the guidance under 'Cabinetry
preparation'. In addition to this, a second Ø57mm
service hole must be also be created through the
shelf and the base of the cavity to route the venting
hose through.
Frameless cabinetry: A 100mm x 200mm cutout
z
must be created at the front of the cabinetry base to
secure the duct to.
Framed cabinetry: A toe kick depth of at least 60mm
z
is required. In addition, a 100mm x 200mm cutout
must be created within the adjacent cabinetry base
to secure the duct to. This cutout should be set
back a minimum of 25mm from the frame edge for
optimal venting.
EXTERNAL VENTING PREPARATION
THROUGH ADJACENT CABINET
FRAMED
FRAMELESS
5
Ø57
200
25
100
A toe kick height of at least 100mm is required.
z
A notched-out Ø57mm service hole should be
z
created through the side wall following the guidance
under 'Cabinetry preparation'.
Frameless cabinetry: A 100mm x 200mm cutout
z
must be created in the base of the adjacent cabinetry
to secure the duct to.
Framed cabinetry: A toe kick depth of at least 60mm
z
is required. In addition, a 100mm x 200mm cutout
must be created within the adjacent cabinetry base
to secure the duct to. This cutout should be set
back a minimum of 25mm from the frame edge for
optimal venting.
*Frameless install illustrated
FRAMED
5
5
Ø57
Ø57
200
100
100
custom framed edge
ISO*
*Frameless install illustrated
THROUGH FLOOR
200
25
There is no minimum toe kick height for venting
z
the DishDrawer™ Dishwasher through the floor
below the cabinetry, the space below the floor
however, must be a sub-area of the house and have
adequate airflow.
A Ø57mm service hole should be created through
z
the side wall following the guidance under 'Cabinetry
preparation'. In addition to this, a Ø57mm service
hole must be also be created through the shelf, the
base of the cavity and the floor to route the venting
hose through.
The duct is not required for this venting method.
z
Ensure all cutout edges are smooth and rounded and
z
the supplied edge protector is fitted if required.
Ensure cutout in the floor is sealed adequately.
z
FRAMED & FRAMELESS
5
Ø57
ISO
11

Advertisement

Table of Contents
loading

This manual is also suitable for:

Single dishdrawer dd60shti9

Table of Contents