Handling
Module
Handling
1. Connect one or two actuators to the control unit.
2. Connect the 24 V side of the power supply to the
control unit.
3. Connect the 230 V AC supply voltage
to the power supply and switch it to ON.
4. Check the direction of travel:
•fBriefly press S4
•fBriefly press S5
5. For one actuator on M1 :
At S2 set DIP-3 to ON.
6. For two actuators:
At S2 set DIP-3 to OFF.
7. Switch S1:
•fDIP-1 = OFF (radio actuator)
•fDIP-2 = OFF (radio light)
20
WARNING
Reverse the connection wires on the motor if
the direction is incorrect.
Result
•fGreen LED flashes or is steady
•fPergola opens
•fPergola closes
•fDeactivating the radio receiver