C. Sidewalls/Surrounds
• Adjacent combustible sidewalls must be located a minimum of 12 in. (305 mm) from the fireplace opening.
Combustible and non-combustible mantel legs, surrounds and stub walls may be constructed within the gridded area,
Figure 6.3.
FLUSH
FRONT
11 1/4 in.
[286 mm]
12 in.
[305 mm]
Figure 6.3
Mantel Leg or Wall Projections (Acceptable on both sides of opening)
D. Frame the Fireplace
Figure 6.4 shows typical framing using combustible materials (2x4 lumber shown).
• Observe all required air space clearances to combustible materials as shown in Figure 6.1 & 6.2.
• Framing across the top of fireplace must be above top standoffs.
14 1/2 in.
(368 mm)
framing
C
B
Figure 6.4
Framing the Fireplace
18
Outdoor Lifestyles by Hearth & Home Technologies • ODVILLA Wood Owners/Install • 4072-345 Rev A • 08/22
4 in.
BRICK
[102 mm]
FRONT
A
9 3/4 in.
[248 mm]
B
12 in.
[305 mm]
A
Model
ODVILLA-36
ODVILLA-42
* If interior of chase will be drywalled, add the thickness to
this measurement.
** Adjust header height for a raised floor under fireplace.
Model
ODVILLA-36
ODVILLA-42
Header MUST NOT be notched!
A
in.
42
mm
1067
in.
48
mm
1219
A
B
Fireplace
Outside
opening
Dimensions
36 in.
41 in.
914 mm
1041 mm
42 in.
47 in.
1067 mm
1194 mm
B*
C**
21 1/2
39 3/4
546
1010
21 1/2
39 3/4
546
1010