Download Print this page

Goodman GPD M Series Installation Instructions Manual page 25

Dual fuel gas-electric heating & cooling units

Advertisement

Check the burner flames for:
1. Good adjustment
2. Stable, soft and blue
3. Not curling, floating, or lifting off.
Burner Flame
At least once a year, prior to or during the heating season,
make a visual check of the burner flames.
NOTE: This will involve removing and reinstalling the heat
exchanger door on the unit, which is held by two screws.
If you are uncertain about your ability to do this, contact a
qualified servicer.
If a strong wind is blowing, it may alter the airflow pattern
within the unit enough that an inspection of the burner
flames is not possible.
1. Shut off electric power and gas supply to the unit.
2. Remove the screws securing the manifold to the
burner retention bracket. Remove the manifold and
rotate each burner counterclockwise to remove.
3. Remove the burners.
4. Use a bottle brush to clean burner insert and inside
of the burners.
5. Replace burners and manifold, inspect the burner
assembly for proper seating of burners in retention
slots.
6. Reconnect electrical power and gas supply.
Manifold
Manifold Assembly
Burner
Burner
Bracket
25
For further information on the yearly inspection, consult the
User Manual. It is recommended that a qualified servicer
inspect and service the unit at least once each year.
Turn the unit on at the thermostat. Wait a few minutes,
since any dislodged dust will alter the normal flame
appearance. Flames should be predominantly blue and
directed into the tubes. They should not be yellow. They
should extend directly outward from the burner ports
without curling downward, floating or lifting off the ports.
ACCESSORIES AND FUNCTIONAL PARTS
Sheet Metal Accessories
Additional accessories can be purchased to fit specific
application needs. Parts and instructions are available from
your distributor.
Functional Parts
FUNCTIONAL PARTS
Auxiliary Limit Switch
Blower Housing
Circulator Blower Motor
Blower Wheel
Burner
Capacitor
Compressor
Condenser Coil
Condenser Fan Blade
Condenser Fan Motor
Contactor
Defrost Control
Defrost Thermostat
Gas Manifold
Evaporator Coil
Flame Rollout Switch
Functional Parts List
General Information
1. Refer to the description in Functional Parts List when
ordering any of the listed functional parts. Be sure to
provide the unit model and serial numbers with the
order.
2. Although only functional parts are shown, all sheet
metal parts, doors, etc. may be ordered by description.
3. Parts are available from your distributor.
Flame Sensor
Gas Orifice
Gas Valve
Heat Exchanger
High Limit Switch
High Pressure Switch
Igniter
Ignition Control
Induced Draft Blower
Low Pressure Switch
Pressure Switch
Pressure Switch Hose
Relay
Reversing Valve
Transformer

Advertisement

loading