Grounding and lightning protection requirements
....................................................................................................................................................................................................................................
Product grounding
Overview
This section details the grounding ancillary items and grounding connection points on the
9764 Metro Dock module and the 9764 MCO module.
Grounding ancillary items
The following grounding related ancillary items can be ordered from Alcatel-Lucent.
Table 4-1
Item
Grounding cable
Basic installation kit
Note: Where grounding materials are locally supplied it is important that all
grounding system material (cable, connectors, buses, etc.) are of high quality, that
resist deterioration and require little or no maintenance.
9764 Metro Dock module grounding point
The following figure shows the grounding point on the Alcatel-Lucent 9764 Metro Dock.
The ground cable can be connected directly to the 9764 Metro Dock via a single hole
grounding lug or preferably a double hole grounding lug crimped onto the cable. M6
screws are used to attach the ground cable to the grounding point on the 9764 Metro Dock
module.
Single lug
ground point
....................................................................................................................................................................................................................................
4-4
Grounding materials
Side view
of Metro Dock
Alcatel-Lucent – Proprietary
Use pursuant to applicable agreements
Description
Green and yellow insulation 10 mm
Metro Dock ground cable, cable lugs, screws and washers
Double lug
ground point
Product grounding
2
(100 meter roll)
Bottom view
of Metro Dock