Product Specifications - Trane BAYHTR1504BRKC Installer's Manual

Supplementary electric heater
Table of Contents

Advertisement

Product Specifications

OUTDOOR UNIT
(a) (b)
POWER CONNS. — V/PH/HZ
(c)
MIN. BRCH. CIR. AMPACITY
BR. CIR. PROT. RTG. — MAX. (AMPS)
COMPRESSOR
NO. USED — NO. STAGES
VOLTS/PH/HZ
R.L. AMPS
(d)
— L.R. AMPS
FACTORY INSTALLED
START COMPONENTS
(e)
INSULATION/SOUND BLANKET
COMPRESSOR HEAT
OUTDOOR FAN
DIA. (IN.) — NO. USED
TYPE DRIVE — NO. SPEEDS
CFM @ 0.0 IN. W.G.
(f)
NO. MOTORS — HP
MOTOR SPEED R.P.M.
VOLTS/PH/HZ
F.L. AMPS
OUTDOOR COIL — TYPE
ROWS — F.P.I.
FACE AREA (SQ. FT.)
TUBE SIZE (IN.)
REFRIGERANT CONTROL
REFRIGERANT
LBS. — R-410A (O.D. UNIT)
(g)
FACTORY SUPPLIED
LINE SIZE — IN. O.D. GAS
(h) (i)
LINE SIZE — IN. O.D. LIQ.
CHARGING SPECIFICATIONS
SUBCOOLING
DIMENSIONS
CRATED (IN.)
WEIGHT
SHIPPING (LBS.)
NET (LBS.)
4A6H5060H-SUB-1A-EN
Page 11 of 20 10/16/2019
MOHS, PLANS EXAMINER
4A6H5060H1000A
208/230/1/60
31
50
DURATION™- SCROLL
1 — 1
208/230/1/60
23.7 — 152.5
NO (Uses BAYKSKT263)
NO
NO
PROPELLER
27.6 — 1
DIRECT — 1
4992
1 — 1/3
850
200/230/1/60
2.80
SPINE FIN™
2 — 24
29.15
3/8
EXPANSION VALVE
10 LBS., 9 OZ
YES
1–1/8
3/8
8°F
H X W X D
51 x 38.7 x 35.1
301
251
REV #1
2405 E AINSWORTH AVE
INSTALL HVAC SYSTEM/PORT OF PASCO
(a)
Certified in accordance with the Air-Source Unitary Air-conditioner
Equipment certification program, which is based on AHRI standard
210/240.
(b)
Rated in accordance with AHRI standard 270.
(c)
Calculated in accordance with Natl. Elec. Codes. Use only HACR
circuit breakers or fuses.
(d)
This value shown for compressor RLA on the unit nameplate and on
this specification sheet is used to compute minimum branch circuit
ampacity and max. fuse size. The value shown is the branch circuit
selection current.
(e)
No means no start components. Yes means quick start kit
components. PTC means positive temperature coefficient starter.
Optional kit shown.
(f)
Standard Air — Dry Coil — Outdoor
(g)
This value approximate. For more precise value see unit nameplate.
(h)
Reference the outdoor unit ship-with literature for refrigerant piping
length and lift guidelines. Reference the refrigerant piping software
pub # 32-3312-xx or refrigerant piping application guide SS-
APG006-xx for long line sets or specialty applications (xx denotes
latest revision).
(i)
Trane outdoor condensing units are factory charged with the system
charge required for the outdoor condensing unit and 15 feet of tested
connecting lines. If connecting line length exceeds 15 feet, then final
refrigerant charge adjustment is necessary. Each additional foot over
15 feet requires 0.6 ozs of refrigerant. See the Installer's Guide for
full charging instructions.
3
.
B19-2396
10/1/2019