Maytag Amana MVS96 Series Installation Instructions Manual page 37

Ultra low nox variable speed gas furnace
Table of Contents

Advertisement

MENU OPTIONS
LED
Display
Aux (condensate switch enabled)
ASE
Enable or disable inverter boost operation. (compressor speed may
t
increase when this feature is on) (inverter only)
Boost mode will operate above this selected temperature. On = boost
tt
mode always on (default = 105°F) (inverter only)
Cooling Airflow Profile setting (default = profile D shown as 4)
CAP
Heat Pump compressor lockout temperature. Furnace will act as
CP
primary heat source below this temperature. (Default = 45°F)
Compressor off delay at the beginning and end of a defrost cycle.
CdL
(default = 30 seconds)
Cooling Airflow Off Delay Time. (default = 60 seconds)
CFd
Resets all cooling settings to a factory default
CL
Cooling Airflow On Delay Time (default = 5 seconds)
Cnd
Control Firmware Revision Number
C
Enable or disable inverter charge mode
C
Select the range that includes the desired compressor RPS for inverter
CP
cooling operation. See inverter manual for menu options
Maximum Compressor RPS for cooling mode (inverter only)
C
Percentage of high stage cooling airflow to run during low stage
CSt
operation (default = 70%)
Cooling Airflow Trim (default 0%)
CtF
High Cooling Airflow Trim for inverter units. See inverter manual for menu
CtH
options and defaults
Intermediate Cooling Airflow Trim for inverter units. See inverter manual
Ct1
for menu options and defaults
Low Cooling Airflow Trim for inverter units. See inverter manual for menu
CtL
options and defaults
Compressor run time between defrost cycles. (default = 30 minutes) (2
dF
stage units)
Enables or disables dehumidification feature in the outdoor unit (default
dHE
= Enabled)
Select "1" to enable dehumidification when the thermostat DH terminal
is energized. Select "0" to enable dehumidification when the thermostat
dHL
DH terminal is de-energized (default = 1)
View 6 most recent fault codes and Clear Fault Codes if desired (outdoor
FCL
communicating units)
Force system into a defrost cycle (inverter units)
FdF
Constant Fan Speed as percent of maximum airflow (Default = 25%)
FSd
Gas Heat Fan Off Delay (default = 90 seconds)
Fd
Gas Heat Fan On Delay (default = 30 seconds)
nd
Percentage of high stage gas heating airflow to run during low stage gas
St
heat operation (default = 70%)
Gas Heat
gH
Menu Description
LED Display
gtF
Gas Heat Airflow Trim (default = 0%)
Maximum Compressor Run Time Between Defrost Cycles (default
HdI
= 120 minutes)
HFd
Heat Pump Heating Airflow Off Delay Time (default = 60 seconds)
Heat Pump Heating Airflow On Delay Time (default = 5 seconds)
Hnd
Select the range that includes the desired compressor RPS for
HP
inverter heating operation. See inverter manual for menu options
HS
Maximum Compressor RPS for Heating Mode (inverter only)
Ht
Reset all heat pump heating settings to factory default.
Percentage of high stage heat pump heating airflow to run during
HSt
low stage operation. (default = 70%)
HtF
Heat Pump Indoor Airflow Trim (default = 0%)
High Heating Airflow Trim for Inverter Units. See inverter manual for
HtH
menu options and defaults
Intermediate Heating Airflow Trim for Inverter Units. See inverter
HtI
manual for menu options and defaults
Low Heating Airflow Trim for Inverter Units. See inverter manual for
HtL
menu options and defaults
View 6 most recent fault codes and clear all fault codes if desired.
LF
(furnace)
Restart communications between the indoor and outdoor unit.
Ln
Select the number of stages for the non-communicating outdoor
DS
unit. Default = OFF meaning no outdoor unit.
Enable Pump Down Mode
PPd
Resets furnace settings to factory defaults.
Fd
Maximum Current Option (system will limit capacity to percentage
SCt
of maximum current) (default = 100%)
Control Shared Data Revision Number
S
St
Resets all outdoor unit settings to factory defaults.
System Verification Test (inverters only)
St
Indoor Airflow for non-communicating outdoor units. (values based
tn
on 400CFM per ton) (default = 3.0 Ton)
Select Outdoor Unit Elevation (SL=same level, OL = outdoor lower,
t
IL = indoor lower) Default = Outdoor Lower
1 = system will try to satisfy the thermostat quickly.
CFS
5 (default) = system will try to satisfy the thermostat more slowly.
Menu is enabled if the CFS menu is set to 6. Select the target time
tgt
the system will attempt to satisfy the thermostat.
Menu is enabled if the CFS menu is set to 6. Select the percentage
SUP
past the target time when the system will transition to gas furnace
operation during heat mode.
Menu is enabled if the CFS is set to 6. (the gas furnace will run
during the next heat call if the heat pump fails to satisfy the
tt
custom target time for this number of consecutive cycles) (default
= 20 cycles)
Menu is enabled if the CFS menu is set to 6. (if low stage gas heat
is able to consecutively satisfy the thermostat under the set target
Utt
time for this number of cycles, the system will transition to the
heat pump for primary heating)
Menu is enabled if the CFS menu is set to 6. (this percentage will
help determine when switching back to heat pump operation is
SdP
appropriate. Default = 20%. If target time = 20 minutes, low stage
furnace operation must satisfy the thermostat by less than 16
minutes. (target time - 20% default = 16 minutes).
37