Connecting the cable

AA
Two electronic cables must be connected to the outdoor unit.
 The connection cord between indoor unit and outdoor unit.
 The power cable between outdoor unit and auxiliary circuit breaker.
 Specially for Russian and European market, before installation, the supply authority should be consulted to
determine the supply system impendance to ensure compliance.
CAUTION
• D uring the unit installation make first refrigerant connections and then electrical connections.
If unit is uninstalled first disconnect electrical cables, then refrigerant connections.
• C onnect the air conditioner to grounding system before performing the electrical connection.
• When installing the unit, you shouldn't use inter connection wire.
Example of Air Conditioner System
When using ELCB for 1 phase
OR
When using ELCB for 3 phase 4 wires
OR
 If an outdoor unit is installed in a place in danger of an electric leak or submergence, you must install
the ELCB or MCCB+ELB