Connecting the cable
AA
Two electronic cables must be connected to the outdoor unit.
The connection cord between indoor unit and outdoor unit .
The power cable between outdoor unit and auxiliary circuit breaker .
Specially for Russian and European market, before installation, the supply authority should be consulted to determine the
supply system impendance to ensure compliance .
• During the unit installation make first refrigerant connections and then electrical connections. If unit is uninstalled
first disconnect electrical cables, then refrigerant connections .
• Connect the air conditioner to grounding system before performing the electrical connection.
• When installing the unit, you shouldn't use inter connection wire.
Example of Air Conditioner System
When using ELCB for 1 phase
OR
When using ELCB for 3 phase 4 wires (ACJXAFNH, ACJXAPNH)
OR
When using ELCB for 3 phase 4 wires (ACKXAPNH)
3 phase 4 wire
(380V-415V~)
Or
ELCB
MCCB +
ELB
Grounding
If an outdoor unit is installed in a place in danger of an electric leak or submergence, you must install the ELCB .