Temp. difference to stop cooling
N08
mode
Temperature to open electronic
N09
safety valve
N10
Temperature to stop solar pump
N11
Constant solar pump operation
r
Temperature
r01
Desired water temperature with HP
r03
Temperature difference to start HP
Start el. heater when water reach
r04
param. r05
Temp. where el. heater replace
r05
compressor
Time delay to start el. heater in
r06
HEATING regime
Start el heater under temperature
r07
param. r08
Air temp. to start el. heater instead
r08
of compressor
r09
Air temp. to start Rapid heat mode
r10
Air temp. to start Heating mode
r11
Circulation pump operation time
r12
Air temp. to force compressor stop
Max water temp. when power
r14
supply from other source (PV
system)
S01
External switch position
S02
Electric overload
S03
Low pressure switch
S04
High pressure switch
S06
Flow switch
T01
Air temperature
T02
Water temperature below
T03
Water temperature above
T04
Evaporator temperature
T05
Suction temperature
T06
Solar temperature
O01
Compressor
O02
Electric heater
O03
4-way valve
O04
Fan high speed
Low fan / /Circulation pump / Solar
O05
pump /Recovery
Running indicator/Circulation pump
O06
/ Solar pump/Solar valve
O07
EEV
ADVICE:
It is a fact that the heat pump will work more efficient if the set water temperature will be set lower. We
recommend that you set the desired water temperature under the parameter "r01" to 45°C and set the cycle
of the antilegionella cycle program to a minimal cycle of 1 month.
IMPORTANT:
The antilegionella cycle is performed with the help of an additional electric heater. If no electric heater or
other heat source is connected, the function will be activated but set temperature will not be reached. In this
1~40°C
50~90 °C
50~90°C
YES/NO
10~60°C
1~20°C
NO/YES
30~90°C
0~450 Min
NO/YES
-20~10°C
0~30°C
10~40°C
0-255S
-30~-5°C
10 ~ 60°C
OPEN/CLOSE
OPEN/CLOSE
OPEN/CLOSE
OPEN/CLOSE
OPEN/CLOSE
-30~97°C
-30~97℃
-30~97℃
-30~97℃
-30~97℃
-3~97℃
ON/OFF
ON/OFF
ON/OFF
ON/OFF
ON/OFF
ON/OFF
ON/OFF
26
10
Service
80
Service
85
User
NO
Service
47
User
5
Service
NO
Service
45
Service
45
User
YES
Service
-10
Service
10
Service
20
Service
60
Service
-15
Service
60
Service
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/

Advertisement

Table of Contents
loading

Related Products for Orca WSW COMPOSITE

Table of Contents