Valve Clearance - Westinghouse WGen12000c User Manual

Table of Contents

Advertisement

Available languages

Available languages

MAINTENANCE
other sources of ignition such as areas with a spark-
producing electric motor or where power tools are
operated.
• Do not store the generator, gasoline near furnaces,
water heaters, or any other appliances that produce
heat or have automatic ignitions.
• With the engine and exhaust system cool and all
surfaces dry, cover the generator to keep out dust. Do
not use a plastic sheet as a dust cover. Non-porous
materials trap moisture and promote rust and corrosion.
LONG TERM STORAGE
Even properly stabilized fuel can leave residue and cause
corrosion if left long term. If storing the generator for over
six months, drain the fuel tank.
DRAINING THE FUEL TANK
If storing the generator for longer than six months, drain
the fuel tank to prevent fuel separation, deterioration, and
deposits in the fuel system.
by slightly compressing it while removing it from the
tank.
Using a commercially available gasoline hand pump
(not included), siphon the gasoline from the fuel tank
into an approved gasoline container. DO NOT use an
electric pump.
OR
Disconnect the fuel line from the bottom of the fuel tank
and allow the fuel to drain into an approved gasoline
container. Reinstall the fuel line.
Start the generator and allow it to run until the generator
engine stops.
Push the battery switch to the OFF position.
Disconnect the battery.

VALVE CLEARANCE

NOTICE
Checking and adjusting valve clearance must be done
when the engine is cold.
Perform this procedure on both cylinders.
Remove the rocker arm cover and carefully remove
the gasket. If the gasket is torn or damaged, it must be
replaced.
Remove the spark plug so the engine can be rotated
more easily.
Rotate the engine to Top Dead Center (TDC) by
momentarily pushing the Start button. Looking through
26 | Westinghouse Outdoor Power Equipment
the spark plug hole, the piston should be at the top (both
valves are closed).
Both the rocker arms should be loose at TDC on the
compression stroke. If they are not, rotate the engine
360°.
Insert a feeler gauge between the rocker arm and the
valve stem to measure valve clearance.
0.0031 – 0.0047 in
(0.08 – 0.12 mm)
8-12 N•m
If an adjustment is necessary, hold the rocker arm pivot
and loosen the pivot adjusting nut.
clearance. Hold the rocker arm pivot and re-tighten the
Perform this procedure for the other valve.
Install the gasket, rocker arm cover, and spark plug.
0.0051 – 0.0067 in
(0.13 – 0.17 mm)
8-12 N•m

Advertisement