Download Print this page

Troubleshooting - Bon Pergola DM45EAF/S Instructions Manual

Advertisement

12 Signal Repeater Function
Press P2 button once(1 jog and 1 beep), press and hold P2 button 5S
P2
(2 jogs and 3 beeps ), the signal repeater function has been activated.
If motor(1 jog and long beep once), the signal repeater function has been
deactivated.
P2
*The factory default mode is OFF.
Signal repeater function off is the factory default mode and only the motor has the
limits, the signal repeater function can be activated. The motor doesn't repeat the signal from the paired address.
13 Enable / Disable Sensitive Stall Detection Function
Press P2 (1 jog and 1 beep ), DOWN(1 jog and 1 beep ), DOWN again
P2
(1 jog and long beep once), sensitive stall detection
If motor jogs twice and beeps 3 times, sensitive stall detection
P2
DOWN
DOWN
is enabled.
*The factory default mode is ON.
14 Resisting / Sensitive Stall Detection Fallback Function
If there is a limit, the motor is in the upward direction, it will be repelled and protected. After rebounding for a
certain distance, it will continue to run upwards. If it encounters resistance at the same position twice, it will
stop after the second resistance rebound. If there is no limit, the motor will run upward and stop after
detecting obstacle.
If there is a limit, the motor is down, it will be repelled and protected. After rebounding for a certain distance,
it will continue to run downward. If it encounters resistance at the same position twice, it will stop after the
second encounter with the rebound. Light resistance does not work; the protection function does not work
during the rebound.
15 50 Times Running Self-calibration Function
It can only be done when the motor is under mode 1; After the upper and lower limit is automatically set,
the motor runs to the lower limit and then runs to the upper limit to run once. When it runs to 50 times, it
automatically corrects the lower limit (resets the lower limit automatically), and stops if fine adjustment or
changes the original limit. Automatically correct the count.
-6-
function
is disabled.
function
Quick Index
Settings
1
Pairing
P1
(hold down 2s)
Stop (hold down 2s)
2
Switch Rotating Direction
Up + Down (hold down 2s)
Manually set upper limit
Up (hold down 2s) → Up + Stop (hold down 2s)
Manually set lower limit
Down (hold down 2s) → Down + Stop (hold down 2s)
3
Upper and Lower Limits Setting
Automatic limits setting
Up (hold down 2s)
Automatically set upper limit,
Up (hold down 2s)
manually set lower limit
Add / Remove Preferred Position
P2 → Stop → Stop
4
Up + Stop (hold down 5s) → Up or Down →
Adjusting the upper limit
Up + Stop (hold down 2s)
5
Adjust Limits
Down + Stop (hold down 5s) → Up or Down →
Adjusting the lower limit
Down + Stop (hold down 2s)
6
Activate / Deactivate Jog / Tilt Mode
Up + Down (hold down 5s) → Stop
P2(a) → P2 (a) → P2(b)
7
Pair / Unpair Additional Emitter
P2(a) → P2 (a) → Stop (b) (hold down 2s)
P1
(hold down 2s)
Stop (b) (hold down 2s)
8
Remove All Emitters
P2 → Stop → P2
9
P2 → Down → P2
Deleting All Limits
10
P2 →
Up
Up
Motor Mode Switching
11
Motor Lower Limit Return Function
P2 → Stop → Down
12
Signal Repeater Function
P2
(hold down 5s)
Enable / Disable Sensitive Stall
13
P2 → Down → Down
Detection Function

Troubleshooting

Issues
Possible causes
Double check power and cable connections, follow wiring
Power Failure Or Incorrect Connection
instructions.
emitter battery is low capacity
Replace battery
The motor has no response
Check antenna on motor is intact and exposed. Check for
Radio interference / shielding
possible source of radio interference.
Out of radio control range
Try control within closer range
Always reserve an individual correctly (refer to motor functions)
The emitter cann't control
Multiple motors are paired to the
Try to use multi-channel emitters to control multi-motor
single motor
same channel.
projects, ensure each channel to control one single motor
Connections are incorrect.
Check connections
The motor doesn't run or starts
too slowly or make loud noise
Incorrect installation or overload
Check installation or overload
The motor stops during the going
The motor has reached the lower limit
Adjust the new lower limit
up or going down.
Running time exceeds 4 min
Consult the sales for more information
-7-
Steps
Down + Stop (hold down 2s)
Solution

Advertisement