Wiring
Three wires:
230V/50Hz
1
Neutral line = Blue
2
Live line = Brown
3
Earth line = Green Yellow

Motor Installation

Drive tube
Step 1 Cut drive tube to required length.
Step 2 Ensure tube edge is clean and burr-free.
②Drive Adapter
①Crown
③Circlip
Bracket
Step 3 Mount correct crown & drive adapter on
Step 4 Align the notches on the crown and drive
the motor. Make sure drive adapter fits firmly and
adapter with the drive tube, slide and fit the motor
crown rotates freely.
into drive tube. Mount idler and bracket on both
ends.
Caution
1. Do not expose motor to humid, damp or extreme temperature conditions.
2. Do not drill into motor.
3. Do not cut the antenna and keep it clear from metal objects.
4. Do not allow children to play with this device.
5. If power cable or connector is damaged, do not use.
6. Ensure correct crown and drive adaptor are used.
7. Ensure power cable and aerial is clear and protected from moving parts.
8. Cable routed through walls shall be properly isolated.
9. Motor is to be mounted in horizontal position only.
10. Before installation, remove unnecessary cords and disable equipment not needed for powered
operation.
11. Installation and programming to be performed by a qualified professional, use or modification outside
the scope of this instruction may void warranty.
-2-
Motor
Drive tube
Bracket
Important Safety Instructions To Be Read Prior To Operation.
Setting Notice
Please read following points of attention carefully before setting.
1. Pls take the wire connnector to protect the extra free wires.
2. Operation:
① The valid interval time of the buttons is within 6S, if there is no operation within 6S, the emitter will exit
the present setting.
② The motor will jog and beep as hint, pls operate after the jog and beep.
3. Set limit position:
① After the upper/lower limit setting,and the upper/lower limit positin can't at the same position.
② After limit setting, with power off and memory function.
③ Limit delete will clear all limit memory.
④ It will exit limit setting when program there is no operation for 2 minutes.
4. If the emitter lost, please setting up again with new emitter.
5. One motor can store maximum 10 channels; after fully stored, if pair new channels, only the last one will be
covered circularly.

Button Instructions

P1 button
P1
Channel
selection"-"
(P1-)
DD1602H
15-channel LCD emitter
Functions of P1 button
1. Cycle Operation:Press P1 button once and every press the motor will run upward → stop → downward → stop circulary.
2. Pairing or Pair Additional Emitter:Press P1 button for 2S, motor jog once, release button and long beep once, motor is
ready for pairing or pair additional emitter.
3. Radio Lock: Press and hold P1 button for 6S, motor jog once, release button and beep twice, the motor enters radio lock
status, the motor won't receive any signal; press P1 button once or the motor is powered off to disable Radio Lock.
4. Switch Direction: Press and hold P1 button for 10S, motor jog once, release button and beep 3 times, the running direction
of the motor has been changed.
5. Reset to Factory Mode: Press and hold P1 button for 14S, motor jog once, release button and beep 4 times, the motor has
been reset to factory mode.
Essential Settings
Step 1 to 3 must be completed to ensure proper operation.
1 Pairing
P1
Press
for 2S (1 jog), release button and long beep once,
P1 button
or repower, within 7S, press STOP for 2S ( 2 jogs and 3 beeps), the
motor has been paired successfully.
P1
STOP
*If no limits, this operation will be pairing; if with limits, this operation will be pairing additional emitter.
2 Switch Rotating Direction
(Optional)
Press UP and motor runs downwards, try below to switch direction.
+
Press and hold UP and DOWN buttons simultaneously for 2S, motor
jog once, the direction has been switched successfully.
UP
DOWN
*The motor needs to be in the reversing operation without limit.
-3-
Display
UP
STOP
DOWN
P2
P2
P2
P2
Lithium Cell
Channel
3V
M
selection"+"
(P1+)