10-2-18 Outdoor OLP over temperature error (One way Inverter Only)

n I
d
o
r o
d
s i
l p
y a
Outdoor display
1.Checklist :
1) Is the sensor placed correctly?
2) Check the service valve is closed
3) Check the compressor locking or gas leak
2. Troubleshooting procedure
Restart after power off.
Restart after power off.
Is the OLP over temperature sensor
error appeared again?
Check the OLP Sensor postion on the Compressor Top
Is the OLP over temperature sensor
Is the OLP over temperature sensor
error appeared again?
error appeared again?
Check the service valve is closed
Check the compressor locking or gas leak
Is the OLP over temperature sensor
error appeared again?
The condition is too poor for air conditioner to operate
Wait until OLP temperature is decreased
Wait until OLP temperature is decreased
Restart after power off
Restart after power off
Exchange the Outdoor PBA
Exchanged the Compressor
E h
10 -20
3-LED DISPLAY
LED1
LED2
LED3
after 10min ~ 1Hr
YES
YES
YES
YES
d h C
D
E
S
C
R
P I
I T
O
N
No display about the outdoor condition
Outdoor OLP over temperature error
NO
NO
NO
NO
E463
Terminate the service
Terminate the service
Terminate the service
Terminate the service
Samsung Electronics