Settings Of The Automatic Functions - Nice UST1K Instructions And Information For Installation And Use

Automatic industrial door control unit
Hide thumbs Also See for UST1K:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 21
Operation functions
In normal operating conditions, the
status of the door and/or the number
of the error present are shown on the
display. In this case position all DIP
switches on OFF!
Automatic closing
Automatic closing is set on the S2 selector.
The closing times can be set on a value between 0 and 240 seconds.
Special function:
If there is a photoelectric barrier, the time is reduced by 5 seconds
after passage.
Time
setting
0
Automatic closing disabled
1
5
seconds
2
10
seconds
3
20
seconds
4
30
seconds
5
45
seconds
6
60
seconds
7
90
seconds
8
120
seconds
9
240
seconds
WARNING:
It is possible to lengthen the duration of the waiting time of a factor
by choice (with selector in position 6 to 9) using the K5 module. The
parameter to be used is P28.
DIP switch functions:
DIP­1 "ON" and 2, 3, 4 "OFF"
Setting of the final positions
DIP­1, 2, 4 "ON" and 3 "OFF"
Precision setting of the final position (upward
movement)
DIP­1, 3, 4 "ON" and 2 "OFF"
Precision setting of the final position
(downward movement)
Automatic adaptation to the ground
DIP 2 = ON
This function can be used if there is an SBA
sensor.
Advance notice traffic lights
DIP 3 = ON
With this function the red traffic lights
(terminals 1+2) begin to flash 3 seconds
before closing of the door.

SETTINGS OF THE AUTOMATIC FUNCTIONS

s2 rotary
switch
Reversed movement function
DIP 4 = ON
The door blocks and reverses its direction for
about 50 cm if the sensitive edge is enabled
during the downward movement.
DIP 4 = OFF
The door blocks and reaches the upper final
position if the sensitive edge is enabled during
the downward movement.
Meaning of display messages
Upper segment:
flashing ­­> upper final position setting in progress
ON ­­> upper final position setting completed
Lower segment:
flashing ­­> lower final position setting in progress
ON­­> lower final position setting completed
In normal operating conditions, the
status of the door and/or the number
of the error present are shown on the
display.
Error 3
sensitive edge tripped, for example
movement UP,
upper final position,
preliminary limit switch
Fault display (represented with flashing):
1
Safety circuit
2
Lower sensitive edge fault
3
Lower sensitive edge tripped
4
Lower final position not reached
(time limit)
5
Upper final position not reached
(time limit)
6
Incorrect direction of rotation of motor
7
Power during lifting deactivation
8
Door in the safety limit switch sector
9
The door is not in one of the final
positions. Correction of the final position
is impossible
0
Digital limit switch error
movement
DOWN,
,
lower final
position.
English – 9

Advertisement

Table of Contents
loading

Table of Contents