Gardner Denver DPB Series Instruction Manual page 17

Blower purge desiccant compressed air dryers
Table of Contents

Advertisement

Left Tower Pressure
Switch LED:
On=Tower Pressurized
Left Tower Drying LED
Left Purge Valve LED
On=valve open
Off=valve closed
Left Inlet Valve LED
On=valve open
Off=valve closed
Left Tower
Heating LED
Filter Service /
Maintenance LED
Vacuum Fluorescent
Text Display
Select switch
Power On LED
Communications Icon
Data Display Switch
6.5.3 Front Panel Operation
1. There are five operating modes for the Heated
Desiccant Dryer Control.
a. Program Mode
b. Setup Mode
c. Alarm & Service Mode
d. Display Mode
e. Test Mode
2. Each Mode is described below.
6.5.4 Program Mode
1. Press and hold
Program Mode.
2. Program Mode is comprised of the screens that are
described below.
3. There are three (3) ways to exit Program Mode.
a. Press
after making the selection in the final
screen.
b. At any screen, press and hold
onds.
c. The controller automatically exits Program Mode
if no button is pressed within 60 seconds.
RS232
and
for 3 seconds to enter
for 3 sec-
Figure 6
Front Panel Overlay
4. Upon exiting Program Mode the controller will switch
to Display Mode.
Screen 1: Select the Language
1. Press
FRANCAIS and ESPANOL.
2. When finished, press
move to next screen.
Screen 2: Select the Service Level
1. Press
SEVERE.
a. NORMAL Service Intervals are:
i. 4000 hours for filters
ii. 8000 hours for desiccant
iii. 8000 hours for valves
Filter Service /
Maintenance LED
Filter Service /
Maintenance LED
Right Tower Pressure
Switch LED:
On=Tower pressurized
Right Tower Drying LED
Right Purge Valve LED
On=valve open
Off=valve closed
Right Tower
Heating LED
Right Inlet Valve LED
On=valve open
Off=valve closed
Enter Switch
Maintenance / Service
Reminder LED
Alarm LED
Reset Switch for Alarm
ENGLISH
to scroll through the choices: ENGLISH,
to save the selection and
SERVICE LEVEL
NORMAL
to toggle between NORMAL and
15