Gardner Denver DPB Series Instruction Manual page 14

Blower purge desiccant compressed air dryers
Table of Contents

Advertisement

DRY GAS
OUTLET
LEFT
CHAMBER
DRYING
WET GAS
INLET
12
V7
F1
O1
M
V5
PI3
PI1
H1
SET @
45 PSIG
1PS
SET @
5 PSIG
3PS
EXH.
(RTD4/HS1)
3
2
1
ENERGY MGMT OPTION
SET @ 176°F
SOL 'C'
RTD 1
SOL 'F'
BD1
V9
M1
Sequence of Operation — Fixed Cycle Operation
Left Chamber Drying – Right Chamber Regenerating (shown)
(continued on next page)
SET @ 165 PSIG
V14
V11
V8
SOL 'E'
V12
V13
O2
V6
1TC
SET @ 370°F
RTD 3
SET @ 650°F
SOL 'D'
SOL 'G'
BD2
V3
V4
V1
V2
NOTES
1.
SYMBOLS ARE PER ANSI Y32.10 "GRAPHIC SYMBOLS FOR FLUID POWER DIAGRAMS. "
2.
AS SHOWN FLOW DIRECTION IS:
3.
SOLENOID VALVES 'B' , 'D' , & 'G' ARE SHOWN ENERGIZED,
SOLENOID VALVES 'A' , 'C' , 'E' , & 'F' ARE SHOWN DE-ENERGIZED.
4.
INDICATES OPTION
Figure 4
F2
DPA
DEWPOINTER OPTION
PR&G
SET AT
100 PSIG
PI2
RIGHT
CHAMBER
SET @
45 PSIG
2PS
SET @
5 PSIG
4PS
REGEN
SET @ 176°F
RTD 2
V10
M2
SOL 'A'
SOL 'B'
LEFT CHAMBER DRYING
RIGHT CHAMBER REGEN
PILOT GAS LINE

Advertisement