Engineer Programming
Quick Keys
 
 
System: Controls: CP-01
Quick Keys

 
Parameter
Key Switch Lock
YES: Only a latched key switch zone can set or unset the system.
Note
When the system has more than one zone defined as latch key switch,
the set/unset operation will occur only after all these zones are set or
unset.
NO: Any means can be used to set or unset the system (keypad, remote
phone operation etc.).
Entry Unset
Determines if the system's disarming depends on the entry time.
YES: Only a remote control can unset the system during the entry time.
Note
The system cannot be unset with a remote control while the system is set.
NO: The system can be unset during any time using any disarming
device.
Parameter
CP-01
This section refers to controls that apply to comply with SIA CP 01.
Exit Restart
This parameter is used to define if an exit time shall restart one
additional time while an entry/exit zone is tripped twice during exit
time.
YES: Exit time will restart for one time only when an entry/exit zone is
tripped during exit time.
NO: Exit time will not be affected if an entry/exit zone is tripped during
exit time.
Default
No
No
Default
No
Page 78
Range
Yes/No
Yes/No
Range
Yes/No