Quick Keys






Parameter
RX Supervise
Specifies how often the system expects to get a signal from the systemʹs
transmitters. If a signal from a zone is not received during the specified
time the zone will be regarded as lost, the system will send a report code
to the alarm receiving centre, and the system status will be "Not Ready".
Note:
0 hours disables supervision.
It is recommended to set the supervision time to a minimum of 3 hours
AC Off Delay
In the case of a loss of AC power, this parameter specifies the delay period
before reporting the event or operating the programmable output. If the
delay time is set to zero, there will be no delay period.
Guard Delay
Specifies the time period that the system will be unset after an authorized
user enters a Guard code.
Swinger Limit
A swinger is a repeated violation of the same zone, often resulting in a
nuisance alarm and usually due to a malfunction, an environmental
problem, or the incorrect installation of a detector or sensor.
This parameter specifies the number of violations of the same zone
during a single set period, before the zone is automatically omitted.
Note
Enter 00 to disable the swinger shutdown.
Redial Wait
The number of seconds between attempts at redialing the same phone
number.
Applies to the ARC Retries parameter, described on page 143 and FM
Retries described on page 156.
Last Exit Sound
Defines the final seconds of the Exit Time for which the beep sound will
change (keypads), indicating that Exit Time period is about to expire.
Default
0
30
30
00
30
00
Page 63
Engineer Programming
Range
0-7 Hours
001-255 minutes
01-99 minutes
00-15 times
reported
0–255 seconds
0–255 seconds